6. Removing the compressor and 4-way valve
(1) Remove the cabinet and panels. (Refer to section 1.)
(2) Remove the inverter assembly. (Refer to section 2.)
(3) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
(4) Detach the brazed part of the suction and the discharge pipe
connected with compressor.
(5) Remove the compressor nuts.
(6) Remove the compressor.
(7) Detach the brazed part of pipes connected with 4-way valve.
Figure 1
Attach the compressor
protector to the
protector holder with the
surface on which the
model name is printed
facing the area hatched
in the figure.
OBH832C
2
(0 MPa).
PHOTOS/FIGURES
Photo 10
Compressor protector
Discharge
temperature
thermistor
62
Discharge pipe
Suction pipe
brazed part
brazed part
Brazed parts of 4-way valve