8

REFRIGERANT SYSTEM DIAGRAM

MUZ-EF25VG
MUZ-EF25VGH
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
MUZ-EF35VG
MUZ-EF42VG
MUZ-EF35VGH
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
OBH832C
4-way valve
Muffler
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
LEV
Capillary tube
ø4.0×ø2.4×240
Stop valve
(with strainar)
4-way valve
Muffler
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
LEV
Capillary tube
ø4.0×ø2.4×240
Stop valve
(with strainar)
Outdoor
Muffler
heat
exchanger
Compressor
Defrost
thermistor
RT61
Capillary tube
ø3.0×ø2.0×100
Refrigerant flow in cooling
Refrigerant flow in heating
Outdoor
Muffler
heat
exchanger
Compressor
Defrost
thermistor
RT61
Refrigerant flow in cooling
Refrigerant flow in heating
16
Unit: mm
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF
Unit: mm
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF