Payload (Continue) - Semtech TBHV110 Reference Manual

Healthy home sensor iaq
Table of Contents

Advertisement

4.1.2 Payload (continue)

Status
Battery
Board Temp
RH
eCO​ 2
© 2019 Browan Communications Inc. All rights reserved.
Sensors status
Bits [0]
Bits [2:1]
Bits[3]
Bits[4]
Bits[5]
Bits[6]
Bits[7]
Battery level
Bits [3:0]
Bits [7:4]
Temperature as measured by on-board NTC
Bits [6:0]
Bit [7]
Relative humidity as measured by the digital sensor
Bits [6:0]
Bit [7]
CO2 equivalent estimate
Bits [15:0]
1 – Trigger Event, 0 – Keep-Alive
RFU
1 – Temperature and humidity​ ​ s ensor,
0 – IAQ Sensor
1 - Temperature status is changed ( 2℃ delta)
1 - RH status is changed (5% RH deltas)
1 - IAQ status is changed (25 IAQ index)
RFU
unsigned value ν, range 1 – 14;
battery voltage in V = (25 + ν) ÷ 10.
RFU
unsigned value τ, range 0 – 127;
temperature in °C = τ - 32.
RFU
measurement range -32 to 95°C
unsigned value in %, range 0-100.
RFU
Estimation of the CO2 level in ppm. The
sensor does not directly measure CO2,but
derives this from the average correlation
between VOCs and CO2 in human's exhaled
breath.
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tbhv110-915Tbhv110-868

Table of Contents