6.5.2.
Diagnosis for malfunction of remote pointer
Prior check
Check "After fitting with optical attachment, slide the power switch to "ON".", "It is set to Touch-Pen Mode (Required for each
input)." and "Registration of an electronic pen (Pairing) is made." in advance.
Refer to
"Supplement 1: [The check of setting for malfunction of remote pointer]"
Procedure of failure-diagnosis
Electronic Pen's failure-analysis mode
Can be quality judging of "Each switch of an electronic pen" and "Light receiving window".
: Remove the optical attachment.
Failure-analysis mode cannot be used when fitted with optical attachment.
[1]How to enter failure-analysis mode
Turn ON the power switch (about 2 seconds) while pressing the menu button.
Function indicator once carries out green lighting, and
goes into button analysis mode.(In the state of
failure-analysis mode, power indicator turns off.)
[2]The Change in failure-analysis mode
Change "button analysis mode" and "coordinates detection
analysis mode" by long pressing of function button
(about 1 second).
Function indicator is green lighting immediately after
going into "button analysis mode", and function indicator
is blue lighting immediately after going into "coordinates
detection analysis mode".
[3]How to exit failure-analysis mode
The power switch is turned OFF.
[Electronic pen quality judging in failure-analysis mode]
Check item
Judgment method
State of
Normal
Function
Abnormal
indicator
Immediately
after
changing a
mode
Does function indicator
light up by judgment
in failure-analysis mode?
When connect the electronic pen
adapter to the USB port of the computer
and Whiteboard Software is started up,
is "Electronic pen adapter is not found"
displayed?
Failure of the electronic pen adapter
Button analysis mode
Check operation of Pen tip switch, Menu
button,Mouse/pen switching button,
Function button.
Press each switch.
White
Off
Green
for the check method.
* Refer to the judgment in the following failure-analysis mode.
No
Yes
No
Yes
Power switch
Power indicator
Pen tip cover
with rim
Pen tip switch
Coordinates detection analysis mode
Check whether the light receiving section
of electronic pen tip detects the coordinate
information of a pen from a plasma panel.
Point the pen tip on the plasma panel.
22
Failure of the electronic pen
Optical attachment
(or environmental factors such
as PC, radio wave interference,
etc.)
Function
indicator
Function button
Mouse/pen
switching button
Menu button
White
Off
Blue