7-8.
FAST
FORWARD
PULLEY ADJUSTMENT
If fast
forward
cannot
be
set
up
correctly,
adjust pulley position as follows.
1.
Set up fast forward
mode
and check
by hand
how
tightly the tape is wound
onto
the take-
up reel.
Fig. 7-21
Detail A
takeup
pulley
usaanare
2.
If the tape pack is too loose, bend the pulley
arm
in the
direction
indicated
by
arrow
in
Fig. 7-21.
Use pliers.
7-9.
TAKE-UP TORQUE
ADJUSTMENT
If take-up
torque
is weak
in the record
and
playback
modes, adjust it as follows.
1.
Place
a full reel of tape on
the supply
reel
table.
Set up the fast forward mode so that
almost all tape is wound onto the take-up reel.
2.
Set
up
the
playback
mode
and
check
the
take-up torque.
;
3.
If take-up
torque
is weak,
turn
the pulley
pressure adjusting nut shown in Fig. 7-21
CW
2 to 3 turns.
;
takeup
reel table
brake arm
stopper
pulley pressure
adjusting nut
ral
takeup link
Fig. 7-20
Takeup pulley