Dress Lead Assy, Speaker To Rotation Coil Using; Purse Lock Ø 9; Dressing Of Pf Board Conn Assy (For Models With Pf Board Only); Cap Assy, High Voltage Installation - Sony TRINITRON KV-SZ252M50 Service Manual

Table of Contents

Advertisement

KV-SZ252M50/M61/M81/N50/N60
2-17. Dress Lead Assy, Speaker to Rotation Coil using Purse Lock
Dress Lead Assy, Speaker to center position of Rotation Coil using purse lock Ø 9 as shown. Make sure Earth
Assy, Coating wire is above Lead Assy, Speaker. This is to keep Lead Assy, Speaker away from Deflection Yoke.
Earth Assy, Coating
wire
Dress Lead Assy, Speaker to
center position of Rotation Coil
using purse lock Ø 9
2-18. Dressing of PF Board Conn Assy
(for models with PF board only)
DGC Connector
Connector Assy,
3P VH
Apply to all SZ252 Narrow 220V CISPR models ONLY
Clamp the ferrite core at the end of the DGC
wire as shown. Position it directly above DGC
Connector's housing
Housing
RM-GA002
Rotation coil
Earth Assy, Coating wire is
above Lead Assy, Speaker
Rotation Coil
Lead Assy, Speaker
(RED+BLK)
DY
Rotation Coil
Attach purse lock Ø 9
here
Lead Assy,
Speaker
DGC Connector is below Conn Assy,
3P VH to keep Conn Assy, 3P VH
away from Heatsink A007 and D604
CN605
D604
A007
Keep wires away from
heatsinks A007, D604 and
conductive parts
Lead Assy,
Lead Assy, Speaker
Speaker
goes behind DGC

2-19. Cap Assy, High Voltage Installation

TVSR Requirement:
1. Keep HV cable away from conductive parts
(distance of 1mm/kV).
2. Keep spacing between edge of anode cap
& conductive parts (distance of 0.5mm/kV).
3. Keep spacing between edge of anode cap &
non-conductive parts (distance of at least 5mm or more).
– 12 –
9
Ø
Pull wire to
the right
Loop Lead Assy, Speaker and
dress directly on to DGC using
purse lock
Ø 9
Pull wire to left
Lead Assy, Speaker
goes behind DGC
Dress Lead Assy, Speaker
directly on to DGC using
purse lock Ø 9
HV Cap
DGC Band
90º
>5mm
Keep distance of
1mm/kV
Keep distance of
0.5mm/kV
Rotation coil
DGC

Advertisement

Table of Contents
loading