Download Print this page

Aliyiqi HF-2 Quick Start Manual

Hf digital display push-pull force gauge

Advertisement

Quick Links

HF digital display push-pull force gauge
1. Purpose
Digital display push-pull gauge is a small, simple, multi-functional and high-precision thrust and pull test
instrument, which is widely used in electronic appliances, construction hardware, light industrial textiles, auto
parts, lighters and other ignition devices, fire equipment, pen making Push-pull load, insertion force test,
destructive test, etc. in lock making, fishing gear, chemical industry, power machinery, scientific research
institutions and other industries. The digital display has high resolution, high sampling speed, and easy to use. It
is a new generation of high-efficiency and high-precision push-pull force testing instrument.
2. Features
1. High precision and high resolution.
2. Five test modes and three display modes are available (MAX degree improves test efficiency).
3. N (Newton), kg (Kilogram), lb (Pound) three measurement units are available for selection and conversion.
4. Gravity acceleration setting function: The user can input the accurate value of the gravity acceleration of the
use place by himself. Make testing and unit conversion more accurate.
5. Peak hold function. Keep the peak display until manually cleared.
6. Automatic peak function, the time can be set freely, from 1 to 9999 seconds.
7. The upper and lower limits can be set for statistical analysis. By setting the upper and lower limits to exceed
the limited range, the buzzer can alarm.
8. Data storage function, can store 447 test values.
9. Data output function, the data can be input into the computer through the data line for various analysis. (It can
also be applied to multiple instruments to perform various analyses with a computer at the same time.)
10. Green and environmental protection, 10 minutes of no operation automatic shutdown, 10 minutes is the
default, you can set the automatic shutdown to the required automatic shutdown time, when the automatic
shutdown is set to 0, it will not automatically shut down.
11. High-quality charging power supply. The charging voltage is available from 100V to 240V, which can be
adapted to most areas in China and abroad. There are also short-circuit, leakage, and overload protection
functions.
12. The unique switch contact on-off force test function makes the switch on-off force test more accurate.
13. 6-bit large screen display.
14. Low battery detection and shutdown. When the battery is low, it will automatically shut down to prevent
inaccurate measurement caused by insufficient battery.
Second, the shape and structure

Advertisement

loading
Need help?

Need help?

Do you have a question about the HF-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aliyiqi HF-2

  • Page 1 HF digital display push-pull force gauge 1. Purpose Digital display push-pull gauge is a small, simple, multi-functional and high-precision thrust and pull test instrument, which is widely used in electronic appliances, construction hardware, light industrial textiles, auto parts, lighters and other ignition devices, fire equipment, pen making Push-pull load, insertion force test, destructive test, etc.
  • Page 2 Built-in sensor...
  • Page 4 Specification range Size / mm Equivalent to 50 ~ 500N 5 ~ 50Kg 12.7 1K ~ 5KN 100 ~ 500Kg 19.1 10KN 25.4 20 ~ 50KN 2 ~ 5t 25.4 100KN 200KN M36 × 3 S-type sensor Sensor external Specification range Size / mm ΦA ΦB...
  • Page 5 Specification range Size / mm φB φ Equivalent to 1000 ~ 5000N 100 ~ 500Kg 16 × 1.5 10 ~ 50 1 ~ 5t 68.5 36 × 3 Internal thread cylindrical sensor Specification range Size / mm ΦB Equivalent to t 100 ~ 200 10 ~ 20 M42 ×...
  • Page 6 4. Model specifications Five, screen display...
  • Page 7 ①, three kinds of display: after booting, when there is no character display, it means \"track mode \" (real-time load measurement mode), the value on the screen changes with the change of load; press \"peak \" key here When \"PEAK \" is displayed, it indicates Peak mode (peak hold measurement mode), and the display shows the peak value until it is manually cleared;...
  • Page 8 1. \"Boot \" key When this button is pressed, the power is turned on and the model number is displayed. After booting, before you press \"Clear \" to clear, the zero drift value of the analog signal may be displayed on the screen, just press \"Clear \"...
  • Page 9 Seven, boot display Eight, function introduction 1. Setting function a. Mode switching: After the boot is complete, press \"Settings \" key, \"TEST \" appears, press \"Settings\" key again, 0001 mode appears, use \"Keys can choose different modes. As shown in the figure below: 0001 Standard test mode (factory default mode): In this mode, three states can be set, namely real-time load state, peak hold state and automatic peak state.
  • Page 10 Press \"Settings \" key in the boot state, the display is \"TEST \", then press \" \"Key, you can view the setting options. \" HIDT \", \" LODT \", \" STOP \", \" LOSET \", \" OFFT \", \" PE.SET \", \"GSET \", \"BACSET \", \"RESET \".
  • Page 11 a. Set the machine stop value for this instrument first: Setting method: Turn on, when the measurement interface is displayed, press \"Settings\" to enter the machine stop value setting (display After (STOP), set its value to the preset value. b. There is a signal output jack on the right side of this instrument (see \"Outline Structure Diagram \" above). Insert one end of the signal output line into this jack (socket) and the other end into the electric test bench produced by our company The jack (socket) marked as signal input on the top (this signal output line is the standard accessory of the electric test bench).
  • Page 12 3. After the test is completed, unload the load, turn off the power, remove the fixture, and clean the objects back into the tool box for the next use. 10. Introduction to storing data and connecting to a computer 1. Store data Press \"Save \"...
  • Page 13 C. Do not use the instrument beyond the MAX range. Otherwise, the sensor may be damaged or even an accident may occur. d. When the test value exceeds 100% of full scale, the buzzer will continue to sound. In this case, please quickly release the added load or reduce the load.
  • Page 14 Thirteen, outline and installation dimensions 14. List of random attachments...
  • Page 15 Compression Stretching Extension Mounting Inspection Certificate of charger Instructions fixture fixture screws certificate conformity HF-2 HF-3 HF-5 HF-10 HF-20 HF-30 HF-50 HF-100 HF-200 HF-300 HF-500 HF-1000 (built- HF-1000 (external) HF-2000 HF-3000 HF-5000 HF-10K HF-20K HF-30K HF-50K HF-100K HF-200K HF-300K HF-500K...