1.1

Documentation required

The following documentation is needed for repair procedures:
• Instruction booklet for specific model
• Technical documentation for specific model (diagrams, exploded view, sympton cure and
service manual)
1.2

Tools and resources

As well as the standard equipment, the following is required:
Qty.
Description
1
Screwdriver
1
Pliers for Oetiker clamps
1
CC -A - Vdc tester
1
Digital thermometer
1
SSC (Saeco Service Center)

1.3 Material

Description
Thermal paste
Descaler
Grease solvent
Silicone grease

1.4 Safety warnings

We recommend you consult the technical manual of the machine before performing any mainte-
nance work.
Observe all applicable standards relating to the repair of electrical appliances.
Always disconnect the power plug from the mains before beginning repair work.
Always disconnect the power plug from the mains before beginning repair work.
Simply turning off the main machine power switch is not an adequate safety
precaution.
This domestic appliance is rated as insulation class I.
On completion of the repair work, insulation and dielectric rigidity tests must be
performed.
Disassembling the machine, the operator must pay attention to hot and under
Pressure parts: boiler, pin-boiler, valves, dispensing, steam tube, brew unit,
connections and pipes to avoid burns. Please refer to specific hydraulic circuit
(Image1) to know the parts in detail.
The machine hydraulic circuit can reach maximum pressure of 16/18 bar.
To operate in safety condition is recommended to perform the Steam Out procedure in
order to remove the pressure and hot water inside the hydraulic circuit.
When the machine arrives at the Service Center in descaling mode interrupted, or making Descal-
ing , be very careful not to come into contact with the Descaler.
After the product has been repaired, it should function properly and has to meet the safety re-
quirements and legal regulations as officially laid down at this moment
Notes
Torx T 10
Scale limit > 150°C
Programmer
Notes
Heating element > 200°C
Saeco Entkalker
Personal preference