Summary of Contents for NICOLAZZI Canterbury Z2632
Page 1
Classic Prov Swiv Basin Twinner Lever Handle Art: Z2632 Specifications Available replacement handles: • Handmade in Italy since 1960 • ¼ Turn valves handmade at Nicolazzi Factory • Lead Free Brass Compliant to AZ/NZS 3718 • Suitable even and uneven pressure WM22315 AS/NZS3662 •...
Page 2
420 kPa or less pressure than 270 kPa may affect the diverting action in side spray tap ware. Do not use any Nicolazzi tap ware with sulphurous water. The minimum temperature for all tap ware is 10 degrees Celsius . Below 10 degrees Celsius will void the warranty.
Page 3
Installation Instructions Model : Z2632 ❶ Preparation Tap body Flush out the pipework to remove any foreign matter. Tap body cut out hole sizes : Maximum 33mm diameter. Under side clearance : Maximum 55mm ❷ Install the pop-up waste body top section 1, and waste body bottom section 4, to the basin as shown.
Page 4
Installation Instructions Model : Z2632 ❶ Install the water supply hose 6, into tap the body 5. - Note: Hand tighten only, DO NOT over tighten- 6! ❷ Install the second water supply hose 7, on to tap body 5. - Note: Hand tighten the supply hose only, DO NOT over tighten- 7! ❸...
Page 5
Installation Instructions Model : Z2632 ❹ Feed the O-ring 9, over the water supply hoses. Note: Feed the water supply hoses through the cut out hole, ensuring that they are not bent or kinked, as this could result in permanent damage or leakage.
Installation Instructions Model : Z2632 Install the vertical waste pop-up rod 13, by Check the position of the tap on the counter top, ❻ ❼ feeding it through the hole in the top of the tap and then tighten the nut using a 13mm spanner or body.
Page 7
Spare Parts list Model : Z2632 Further information Phone (03) 9761 4603 sales@sinkandtap.com.au...
Page 8
Spare Parts list Model : Z2632 Further information Phone (03) 9761 4603 sales@sinkandtap.com.au...
Page 9
Care and Maintenance Instructions Model : Z2632 Removing and replacing a handle MODEL SHOWN :Z2632 ❶ ❷ Unscrew and remove the indice button Using a Philips head screw driver, unscrew A, from the tap handle body. the handle retaining screw. ...
Page 10
Care and Maintenance Instructions Model : Z2632 MAINTENANCE FOR SINGLE HOLE TWO LEVER TAP WARE INSTRUCTIONS FOR REPLACEMENT OF THE HOT OR COLD CARTRIDGE Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or kinking of supply hoses.
Page 11
Care and Maintenance Instructions Model : Z2632 LOW FLOW OR NO FLOW TROUBLESHOOTING INSTRUCTIONS Current bathroom taps have a max flow rate of 7 Litres per minute from the aerator and the hand spray. If you are experiencing low flow from the spout: Do not change the cartridge •...
Page 12
Care of external finishes Nicolazzi products are all authentic finishes that have not been coated with any product. After each use, pat the fixture down to remove any excess water. This will prevent any water spotting or mineral build-up. Use only soft liquid soap and water to clean the surface.