Performance Of Your Amplifier: Specifications
Power Consumption and Thermal Emissions — E45
Mains
Load
(V)
(R)
No Sig'l
1.0
240
8
1.0
240
4
1.0
240
2
2.0
120
8
2.0
120
4
2.0
120
2
No Sig'l = Quiescent, Light = Crest Factor of 7.8(18dB),
Average = Crest Factor of 4.8(14dB), Heavy = Crest Factor of 2.8(9dB)
For details of measurement methods please refer to the Technical Support area of our website.
PRC Settings and Maximum Output
Power Reduction Control Setting
E Series – E45 Operating Instructions
Current Draw
(A)
Light
Average
Heavy
1.7
2.7
5.5
2.4
4.5
10.1
3.2
6.9
16.5
3.4
5.5
11.1
4.8
9.0
20.2
6.4
13.7
33.1
Maximum Power into 8 ohms (W)
-2dB PRC
-4dB PRC
-6dB PRC
Maximum Power into 4 ohms (W)
-2dB PRC
-4dB PRC
-6dB PRC
Maximum Power into 2 ohms (W)
-2dB PRC
-4dB PRC
-6dB PRC
Thermal Emissions
(W)
No Sig'l
Light
Average
240
281
344
240
322
447
240
370
589
240
281
244
240
322
447
240
370
589
Per Channel
Bridged Pair
1250
790
500
320
2500
1600
1000
630
4200
2700
1700
1050
Heavy
510
780
1163
510
780
1163
5000
3150
1990
1260
8400
5300
3300
2100
N/A
N/A
N/A
N/A