FUNCTION SETTINGS
5-3-1-1-2 Peak Hold, Bottom Hold, Peak to Peak Hold, Peak to Peak Hold / 2
When the external trigger turns ON, the data of any sampling interval is held as the judgment
value (JUDGE.V).
The hold action can be changed with the trigger mode setting.
Peak Hold (Trigger mode: Hold)
External trigger input ON starts the hold state. External trigger input OFF releases the hold
state. When hold is released, the peak value is cleared and updated whenever necessary.
Timing chart
HIGH set value
LOW set value
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. The judgment value (JUDGE.V) is held while the external trigger input is ON.
2. If the reset input turns ON while the external trigger input is OFF, an indeterminate state oc-
curs during the response time.
3. If the reset input turns ON while the external trigger input is ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
5-30
Ramco National
Normal measured value (NORM.V)*
Judgment value
(JUDGE.V)
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
www.PanasonicSensors.com
Indeterminate state is held.