Peak To Peak Hold / 2 - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

FUNCTION SETTINGS
Sample Hold (Trigger mode: One-shot)
Hold is refreshed each time the external trigger input turns ON (rising edge).
Timing chart
HIGH set value
LOW set value
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. When the power is turned ON, the indeterminate state is held until the external trigger input
turns ON.
2. When the external trigger input turns ON (rising edge), the judgment value (JUDGE.V) is held.
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
Setting item
Setting item
Measurement mode
(MEAS)
Setting item
Trigger mode (TRG)
5-28
Ramco National
Judgment value
(JUDGE.V)
Set values
Sample hold (S-H)
Peak hold (P-H)
Bottom hold (B-H)
Peak to peak hold (P-P)
Peak to peak hold / 2 (P-P/2)
NG hold (NG-H)
Self sample hold (SLF.S-H)
Self peak hold (SLF.P-H)
Self bottom hold (SLF.B-H)
Set values
Hold (HOLD)
One-shot (1SHOT)
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
www.PanasonicSensors.com
Normal measured
value (NORM.V)*
Default value
S-H
Default value
HOLD
1-800-280-6933