Mitsubishi Electric PUZ-ZM200YKA2-ET Service Manual page 32

Table of Contents

Advertisement

Indoor unit model
Indoor unit power supply
Indoor unit input capacity
Main switch (Breaker)
Indoor unit power supply
Indoor unit power supply earth
Indoor unit-Outdoor unit
Indoor unit-Outdoor unit earth
Remote controller-Indoor unit
Indoor unit L-N
Indoor unit-Outdoor unit S1-S2
Indoor unit-Outdoor unit S2-S3
Remote controller-Indoor unit
*1
A breaker with at least 3 mm contact separation in each pole shall be provided. Use earth leakage breaker (NV).
The breaker shall be provided to ensure disconnection of all active phase conductor of the supply.
*2
Maximum 80 m
*3
Maximum 500 m (When using 2 remote controllers, the maximum wiring length for the remote controller cables is 200 m.)
*4
The figures are NOT always against the ground.
Notes: 1. Wiring size must comply with the applicable local and national code.
2. Power supply cables and indoor unit/outdoor unit connecting cables shall not be lighter than
polychloroprene sheathed flexible cable. (Design 60245 IEC 57)
3. Install an earth line longer than power cables.
8-3. INDOOR – OUTDOOR CONNECTING CABLE
The cable shall not be lighter than design 60245 IEC or 60227 IEC.
Outdoor power supply
Indoor unit-Outdoor unit
Indoor unit-Outdoor unit earth
Note: The maximum cable length may vary depending on the condition of installation, humidity or materials, etc.
Indoor/Outdoor separate
power supply
Indoor unit-Outdoor unit
Indoor unit-Outdoor unit earth
Note: The optional indoor power supply terminal kit is necessary.
Be sure to connect the indoor-outdoor connecting cables directly to the units (no intermediate connections).
Intermediate connections can lead to communication errors if water enters the cables and causes insufficient
insulation to ground or a poor electrical contact at the intermediate connection point.
INDOOR-OUTDOOR CONNECTING CABLE
Cross section of cable
Round
Flat
Flat
Round
Note: Power supply cords of appliances shall not be lighter than design 60245 IEC or 227 IEC.
*1: In case that cable with stripe of yellow and green is available.
*2: In case of regular polarity connection (S1-S2-S3), wire size is 1.5 mm 2 .
*3: In case of regular polarity connection (S1-S2-S3).
*4: In the flat cables are connected as this picture, they can be used up to 30 m.
*5: Mentioned cable length is just a reference value.
It may be different depending on the condition of installation, humidity or materials, etc.
OCH771C
*1
*2
*3
*4
*4
*4
*4
Max. 45 m
3 o 1.5 (polar)
1 o Min 1.5
2
Wire size (mm
)
Number of wires
2.5
3
2.5
3
1.5
4
2.5
4
ZM35–140
~/N (single), 50 Hz, 230 V
16 A
3 × Min 1.5
1 × Min 1.5
2 × Min 0.3
2 × 0.3 (Non-polar)
230 VAC
28 VDC
12 VDC
Wire No. o Size (mm²)
Max. 50 m
3 o 2.5 (polar)
3 o 2.5 (polar) and S3 separated
1 o Min 2.5
Wire No. o Size (mm²)
Max. 80 m
2 o Min 0.3
Polarity
Clockwise: S1-S2-S3
* Pay attention to stripe of yellow and green
Not applicable
(Because center wire has no cover finish)
From left to right : S1-Open-S2-S3
Clockwise: S1-S2-S3-Open
* Connect S1 and S3 to the opposite angle
S1
S2
32
Max. 80 m
1 o Min 2.5
L (m)*5
(30)
*1
Not applicable
*4
(18)
*2
(30)
*3
(3C Flat cable × 2)
S3