Operating Your Transmitter 10 - Progress Lighting AirPro P250110 Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

Installing the Battery
Install a 12V MN21/A23 battery (included) into the
remote control. To prevent damage to the remote
control, remove the battery if not used for long
periods. (Fig. 17)
Figure 17
Remote Control Button Definitions:
These six buttons are used to set the fan speed as
follows:
I = minimum speed
II = low speed
III = medium low speed
IV = medium speed
V = medium high speed
VI = high speed
button: Turns the fan off.
button: Controls fan direction.
button: This button is to control optional light
on or off. Press and hold the button to activate the
dimmer function.
Your DC brushless motor is equipped with an
automatically learned type remote control. There are
no frequency switches on the receiver; the receiver
unit will automatically scan the frequency from
the remote control if any changes are made. The
frequency settings on the transmitter should be
changed ONLY in case of interference or if a
second or more ceiling fans with the same type
of control system are installed in the same
structure.
Setting the Remote Control
Follow the below steps to set the remote control:
The auto learning function will only mandate within
60 seconds when turning the fan's AC power ON.

Operating Your Transmitter 10.

From the back of the transmitter, with the fan's
power off, restore power to the fan. Press and hold
"SET" button for about 5 seconds and release. If
optional light kit is installed, the light kit will flash
twice and the signal light on the hand held transmitter
will come on when the button is pressed. The fan
has completed the pairing process with the remote
control and is ready for use. (Fig. 19)
NOTE: If the self calibration test failed, turn the
AC power off; restore power and process the self
calibration test again.
NOTE: During self calibration test, the remote is
non-fuctional.
NOTE: The learning frequency function and self
calibration test will continue to retain the last set
frequency and calibration set even when the AC
power is shut off. If the frequency is changed the
self calibration test will occur again.
Over 80W protection: When the receiver detects
motor power consumption which is greater than
80W, the receiver power will be stopped and
operation will immediately discontinue. Wait for 5
seconds and then turn the receiver power back on.

Advertisement

Chapters

Table of Contents
loading

Table of Contents