Download Print this page

Yale 150 Series Installation Instructions Manual page 4

Non-handed door closer

Advertisement

150 Top Jamb Arm Installation (Right Hand Shown)
1. Prepare door and frame.
1-1/2
(38)
1-3/4
(44)
2. Mount closer to frame.
or
x4
4. Connect arms, preload spring, and
tighten set screw.
90°
3rd
Rotate elbow until Hold
Open arm is perpendicular
The 150 Hold Open Closer - Top Jamb Mount has now been installed.
��
Go to page 2 for closer adjustments and decorative cap or cover installation.
4
9-1/16
(230)
3/4
(19)
1/2
(13)
6
(152)
3. Remove dial from Hold Open arm and install separate arms.
Rotating arm
preloads closer
spring power.
1st
2nd
to frame.
Copyright © 2019, 2023 ,ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the
express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Approved 2023-02-24
150 Series Hold Open Door Closer
Opening
A
to 100°
101° to 120°
*121° to 180°
Top of
Door
*Door/Wall/Hardware/Jamb conditions permitting
C L
1st
Dial DOWN
Left and
Right Hand
5. Set Hold Open.
70° - 180°
3rd
Counterclockwise
to tighten.
Dimension "A"
7-1/2 (191)
6 (152)
3-1/2 (89)
A longer connecting rod
is required for reveals
greater than 3" (76mm)
2nd
or
x2
Flat
Keep door open in position until
dial screw secures dial.
1st
1st
70° - 180°
2nd
2nd
LH:
RH:
Clockwise
to tighten.
80-9350-3504-010 Rev 2 02/23
Reveal
RH and LH:
Position flat at S
3rd

Advertisement

loading

This manual is also suitable for:

151