Check before turning on the EVAstream Check before using the EVAstream Maintenance and repairs Disposal Decommissioning Disposal Attachment 1 - Norm Compliance Attachment 2 - Enviromental conditions use EVAstream Attachment 3 - Water values Attachment 4 - Unintended uses EVAstream Mounting - Installation...
Risk of product damage. Prolonged disturbance of frequency may permanently damage the equipment. The general terms and conditions of EVA Tech B.V. apply to all our offers and agreements. EVA Tech Never place multiple cables in one conduit. B.V. expressly rejects the applicability of the general (purchasing) conditions of counterparties. The Never place the motor control unit near a frequency controller.
To create the optimal swimming experience for the customer, it is important to think carefully about the positioning of the EVAstream in the design phase, for example in relation to elements such as stairs and platforms. Such ‘obstacles’ can cause a less pleasant swimming experience. For optimal water flow, the EVAstream should be placed in the middle of the pool wall in a symmetrically designed pool.
For instructions on how to mount the turbine, go to 5.4. 2. Motor Contol Unit The motor control unit (MCU) of the EVAstream is placed in the technical area near the pool (a dry and condensation-free environment, zone 2). Ensure that the MCU is placed with the cable glands facing down.
When the EVAstream is permanently mounted in the pool, it must be grounded. For safety reasons, it is not allowed to mount lights other than EVA Optic to the EVAstream motor control unit. Make sure that the EVAstream cable (or any other cabling!) cannot be sucked in by the machine.
Page 7
Mounting depth: 250 mm below water level. Mounting depth: 250 mm below water level. Mount the EVAstream horizontally on wall, in the middle of the poolwall. Mount the EVAstream horizontally on wall, in the middle of the poolwall. Please note that the fixed stainless steel parts must be connected to the ground...
EVA Piezo mounted on an installation niche 1. EVAstream installation niche PP Mount the EVA Piezo in a place in the pool where you can use it easily Mounting depth: 250 mm below water level (centre of the turbine). Mount the EVAstream horizontally on in the middle of the poolwall.
Page 9
Remove the ribs 2. EVAstream installation niche POLY Mounting depth: 250 mm below water level (centre of the turbine). Mount the EVAstream horizontally in the middle of the poolwall. See 5.5 (page 17) for mounting the turbine. 449mm 1. Remove the ribs with a saw suitable for plastic Use a saw suitable for plastic and saw off the ribs according to the blue dotted line.
Mounting the EVAstream turbine 1. Mount the bracket in the niche 3. Put the turbine cables through cable glands Use the washers and M12 nuts. Use red, orange and black cables. Do not change the colors of the cables! 2. The bracket is still adjustable 4.
Page 11
6. Mount the adjusting plate to the niche 8. Remove the adjustment plate To ensure the correct horizontal position of the turbine This was only used to ensure the correct horizontal position of the turbine EVAstream www.evaoptic.com EVAstream Mounting - Installation...
Page 12
12. Mount the conduit pipes Use the M5x12 screws with a stainless steel frontplate. The cables need to be placed in separate conduit pipes. Use the M5x16 screws with an ABS frontplate. EVAstream www.evaoptic.com EVAstream Mounting - Installation Mounting - Installation...
Optional - Cable extension 1. Dismantling the cables 3. Place the EVA connection box Make sure the cables are properly finished. Dismantling length should be 16 mm. The cable connection box must be placed above the ground (accessible) 2. Choose your cable 4.
Page 14
5. Mount the conduit pipes The cables need to be placed in separate conduit pipes and close the connection box. EVAstream www.evaoptic.com EVAstream Mounting - Installation Mounting - Installation...
1. Determine swimming zone You start by determining the swimming zone of the user. Did he or she choose an EVAstream Fit, Pro or Max? Then you can use the images to determine exactly what the user’s swimming zone is. This is always the same per type, regardless of the height of the swimmer.
Never open the turbine. Any form of maintenance or repair must be carried out at the factory of EVA Tech B.V. In case of an established defect, the machine must be dismantled and transported to the EVA Tech B.V.
Page 17
Attachment 1 Attachment 2 Norm compliance Environmental conditions use EVAstream EMC Directive: 2014/30/EU Low-voltage LVD Directive: 2014/35/EU Ambient temperature of power supply box (mounting in a dry condensation-free room): EMI Electromagnetic Emission EN 60364-4-41 0ºC to 32ºC EN 55032 (CISPR32) Class A, B...
Page 18
Water Values Unintended uses The user of the EVAstream is responsible for providing the right conditions for an optimal product life cycle. To - Not for use in potentially explosive areas. fulfil the warranty conditions, the EVAstream should only be used in basins with a water composition within - Not for use in an aggressive environment (gases, acids, vapours, substances, oils).
Page 19
Eva Tech B.V. De Velde 1 8064 PH Zwartsluis The Netherlands www.evaoptic.com March 2023 – V1.0...
Need help?
Do you have a question about the EVAstream and is the answer not in the manual?
Questions and answers