6.2.2.
If applicable, connect the vacuum suction hose to the dust extractor connector on your tool with the supplied adaptor.
6.2.3.
Switch the vacuum cleaner to position II, as described in Switching ON/OFF. The moment you switch on the power tool, the vacuum
cleaner will also switch on. Once the electrical appliance has been switched off, the vacuum cleaner switches off following a time lapse
(around 5 seconds) to allow the suction tube to be emptied.
6.3.

POWER REGULATOR

6.3.1.
The airflow can be continuously adjusted by turning the power regulator (Fig. 14).
MIN: Reduced suction for applications which generate a low level of dust.
MAX: Maximum suction performance for use in applications which generate a high level of dust.
6.4.
FILTER CLEANING OPERATION
IMPORTANT: Only perform the filter cleaning operation when the cartridge filter is installed.
6.4.1.
After continuous dry vacuuming operation, air flow will decrease due to heavy accumulation of material and debris on the cartridge
filter. This vacuum is equipped with integrated filter cleaning to increase dust collection efficiency.
6.4.2.
When reduction of air flow (≤20m/s) has occurred during operation, the air flow indicator next to the filter cleaning button located on top
of the power head will admit a flashing red LED. If the suction performance diminishes, you can improve the suction power with the
help of the filter cleaning system (Fig. 15).
6.4.3.
Position the end of the suction hose nozzle into the channel located within the filter cleaner button.
6.4.4.
Move the on/off switch to the "I" position.
6.4.5.
Turn the power regulator to the MAX position.
6.4.6.
Press the filter cleaning button down and hold it down for 3-4 seconds (Fig. 16).
6.4.7.
Repeat the process two more times.
6.5.
WET AND DRY VACUUMING OPERATION
WARNING! ENSURE YOU READ, UNDERSTAND AND APPLY SECTION ENTITLED 'SAFETY INFORMATION'.
WARNING! DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPOURS, OR EXPLOSIVE DUSTS IN THE AIR.
FLAMMABLE GASES OR VAPOURS INCLUDE BUT ARE NOT LIMITED TO; LIGHTER FLUID, SOLVENT TYPE CLEANERS,
OIL-BASE PAINTS, GASOLINE, ALCOHOL OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO;
COAL, MAGNESIUM, GRAIN OR GUN POWDER.
6.5.1.
Verify that the correct filter is installed and the container latches are secured.
6.5.2.
Secure the locking end of the hose into the vacuum suction port.
6.5.3.
Push the desired accessories onto the hose nozzle. The air flow regulation allows you to change vacuum cleaner suction. For best
cleaning results, fully close the air flow regulation (Fig. 17).
6.5.4.
Plug the power cord into a power outlet.
6.5.5.
Turn on the motor by assigning the switch to the "I" ON position.
6.5.6.
Once you have completed vacuuming, switch to the "O" OFF position and unplug the power cord from the power outlet.
6.6.
DRY VACUUMING
WARNING! BEFORE INSTALLING, REMOVING OR CLEANING THE VACUUM CLEANER FILTER, ENSURE THAT THE POWER
CORD IS SWITCHED OFF AND UNPLUGGED.
WARNING! ALWAYS USE A P2-RESPIRATOR WHEN VACUUMING HAZARDOUS DUSTS.