TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Non Programmable hides all
Programmable
scheduling features
Selects how the external temperature
Wired Temperature
sensor terminals (T1 & T2) are being
Sensor Installed?
used Choose Outdoor for a wired
outdoor sensor or Remote/Remote
(S84N SU only)
Average for a wired indoor sensor
Select No to skip the rest of the
Advanced HVAC
Settings?
thermostat settings
Enables or disables progressive
Progressive Recovery
recovery
Select if the Heat Blast option is
Display Heat Blast?
displayed
18
Factory default setting
(bold) and setting range
Programmable
Non Programmable
Outdoor
Remote
(Onboard sensor disabled)
Remote Average
(Average with onboard sensor)
No
(No external sensor connected)
No
Yes
Disabled
Enabled
No
Yes
TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Amount of heating when Heat Blast is
Heat Blast Offset
initiated
Extends fan operation 90 seconds
Extended Fan – Heat
after heat call ends
Extends fan operation 90 seconds
Extended Fan – Cool
after cool call ends
Enable or disable Auto Changeover
Auto Changeover
mode
DeadBand
Auto Changeover mode deadband
Auto Changeover
Minimum time between heating and
Time
cooling calls
Field adjustment of controlling
Temp Sensor Offset
temperature sensors
Equipment Minimum
Minimum on time for heating and
On Time
cooling
Factory default setting
(bold) and setting range
3°F (1.5°C)
4°F (2°C)
5°F (25°C)
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
3°F (1.5°C)
2 to 9°F (1 to 45°C)
4 Minutes
1 to 5 Minutes
0°F (0°C)
-4 to 4°F (-2 to +2°C)
2 Minutes
1 to 5 Minutes
19