increase very little, but the response of the transceiver to button-presses and knob
adjustments will become sluggish. Such is indicated by color change of this adjustable
parameter from Yellow to Red as this effect will (likely) increase – particularly if DSP is
activated.
Scope NoSig Adj. - This adjust how low or high the "no signal" baseline will auto-
•
adjust on the spectrum scope. A low number will raise the baseline up while a high
number will lower the baseline.
Wfall NoSig Adj. - This adjust the background and overall brightness of the spectrum
•
scope. A "low" number will brighten the scope while a "high" number will darken the
scope. With the waterfall display one may use the "Wfall Brightness" and "Wfall
Contrast" settings to adjust the brightness and contrast of the waterfall display to suit
your needs.
Wfall Size - This sets the size of the Waterfall display: Normal = The same size as
•
the Spectrum Scope, Medium = Slightly larger, without the banner at the top.