Advertisement

Error
When?
message
Message displayed
right after you
switch the
machine ON
Message displayed
after a short
movement of the
Generic
motor
alarm
The appliance, 6
minutes after
turning on, is still
in heating mode.
Possible causes
NTC (temperature
sensor on both coffee
and steam boiler
Upper or lower limit
microswitch
Feeler board
Main board
Thermal protector
intervention
Heating element does
not work
Main board
38
Solutions
Check connection between sensor and
board; check the ohm resistance:
if it is 0 (short circuit) of infinite (open
circuit), replace it.
Check microswitch and in case replace
Check connection on the main board of
the feeler board and replace if required.
Replace.
Replace.
Replace.
Check connection in case replace.