12.6 INSPECTION STANDARD

12.6.1 ELECTRIC INSPECTION STANDARD

NO.
Item
1
Display
2
Black/White spots
Black/White spots
3
(No switch)
4
Ghost image
5
Flash dot/Multilateral
6
Segment display
Short circuit/Circuit
7
break/Abnormal display
Standard
Clear display Display complete
Display uniform
D≤0.3mm, negligible
0.3mm<D≤0.5mm, N≤7, Allowed
0.5mm<D≤0.6mm, N≤1, Allowed
0.6mm<D, Not allow
L ≤1mm, W≤0.15mm negligible
1.0mm<L ≤4.0mm
0.15mm<W≤0.5mm
N≤4 Allow
L>4.0mm, W>0.5mm, Not allow
Allowed in switching process
Flash points are allowed when
switching screens
Multilateral colors outside the frame
are allowed for fixed screen time
Selection segment are all displayed,
and
other
segments
displayed
after
the
segment
Not Allowed
31
Defect
level
MA
MI
MI
MI
are
not
selection
MA