COMMON AUDIBLE RINGING UNIT
GENERAL
The Common Audible Ringing Unit provides an
audible signal over the paging system when
there is an incoming call. It is used between a
telephone system and the public address
system.
SPECIFICATIONS
Activation
1A2 Bell/Buzzer ICM
PABX Station Port
Contact Closure
Features
Activates via ringing voltage, buzzer voltage
or contact closure
Capable of switching signal to three zones
simultaneously
Uses standard 1A2 key system voltages
Each zone is equipped with a 5 Watt
amplifier and volume control
Screw terminal connection
Compact size, can be mounted on wall or in
cabinet
Automatically switches paging speakers
from paging system to audible signal of the
V-9924C during the ring interval of the
incoming call
Variable pitch control
Two auxiliary contact closures
Other Materials Required
-24VDC power supply
Cat 3 or 5 twisted pair telephone cable
Mounting screws and hardware
V-9924C
Dimensions/Weight
8.20" H x 4.55" W x 2.30" D
(20.83cm H x 11.56cm W x 5.84cm D)
1.3 lbs. (0.59kg)
Power Requirements
The V-9924C requires a -24VDC "B" battery
and draws 50mA idle and 300mA maximum
operating.
Signal Requirements
The V-9924C requires interrupted ringing or
buzzer voltage or dry contact closure to operate.
The output of the V-9924C will follow the
interruptions of the input. The ringing voltage
should be approximately 90VAC and the current
requirement would be 8mA. The buzzer voltage
should be approximately 18VAC and the current
requirement would be 10mA. The V-9924C
pulls approximately 3mA through a dry contact
closure for activation. Ringing and buzzer
voltages cannot be applied simultaneously. Use
only one method of activation.
1
Issue 1
947023

Advertisement

loading

Summary of Contents for Valcom V-9924C

  • Page 1 COMMON AUDIBLE RINGING UNIT GENERAL The Common Audible Ringing Unit provides an audible signal over the paging system when there is an incoming call. It is used between a telephone system and the public address system. SPECIFICATIONS Activation • 1A2 Bell/Buzzer ICM •...
  • Page 2: Installation

    7 and the other side of the dry closure to pin Speaker Connections The V-9924C Common Audible Ringing Unit is capable of switching up to three zones of speakers to the audible signal generated by the unit.
  • Page 3: Operation

    TO REMO VE CO VER LOOSEN SCREW , THE N AC TIVATE L ATC H PLASTIC COVER OPERATION Figure 3 shows a V-9924C simplified schematic. When the V-9924C is idle, 1T IN is shorted to 1T OUT, 1R IN is shorted to 1R OUT, 2T IN is shorted to 2T OUT, 2R IN is shorted to 2R OUT, 3T IN is shorted to 3T OUT and 3R IN is shorted to 3R OUT.
  • Page 4: Technical Assistance

    Call (540) 563-2000 and press 1 for Technical Support or visit our website at http://www.valcom.com. The V-9924C is not field repairable. Valcom equipment contains no user serviceable parts inside. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be...
  • Page 5 This warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation, or use of the product.