Vixen X002518 Instruction Manual page 12

Altazimuth mount telescopes
Table of Contents

Advertisement

Basic Operation
Aligning the Finder Scope
Loosen the alignment clamp knob on the XY red dot
finder and move the upper portion of the dot finder
by holding its front end so that dot finder is parallel
to the telescope tube roughly. Tighten the alignment
clamp knob.
Insert an eyepiece with low magnification into the
eyepiece adapter on the focuser of the telescope.
Choose a conspicuous target in the distance and point the telescope for it to get the
target in the field of view of the eyepiece. Place the target in the center of the field of view.
Turn on the red dot by turning the brightness control dial. The intensity of the
brightness can be varied freely and stop turning the dial at a proper brightness.
*The brightness control dial turns off when the white dot mark on the dial goes back
to directly overhead the white dot mark on the side of the dot finder.
Confirm that a red dot is spotted just above the aiming needle on the bottom of the
finder's field of view which is aligned with the white guideline as shown in the figure.
*The red dot can be seen clearly with a target in the far-off distance if your eyesight
is good enough without spectacles. The red dot may not be seen as a tight point
image or blurred if you have weak eyesight.
A d j u s t t h e d o t f i n d e r b y
t u r n i n g t h e a d j u s t m e n t
knobs on the side of the dot
finder so that the red dot
aims at the same target in
the telescope's eyepiece.
The adjustment knob on the
side of the dot finder moves
the red dot left and right, and
the knob on the back moves
the red dot up and down.
Turn the brightness control dial until it clicks to switch off the red dot. You should
readjust the brightness of the red dot when you use the XY red dot finder in the nights.
*B e c areful n ot to turn the bri ghtnes s c ontrol dial by forc e as it may b e of f the
ali gnment by s hif tin g the d ot fin der b o dy from the brac ket.
H i n t
Use the XY red dot finder so that its red dot is in the center of the field of view.
The red dot is used for sighting regardless of a position of view as long as it can be seen in the dot finder's field of view.
However, sighting from the corner is uncomfortable and it makes you difficult to locate the red dot. It may result in inaccuracy
of the dot finder.
If you are unable to find the red dot, try to sight from a position close to the white guideline.
(PORTA II Telescopes with the XY Red Dot Finder)
Le f t an d Righ t
Le f t and Righ t
M ov em en t
M ove m ent
Up a nd
Up and
Down Mov em ent
Do wn M ov em ent
12
Aligning the Finder Scope
A l i gn m e n t
A l i gn m e n t
C l a m p K no b
C l a m p K no b
Ta r g et
Ta r g e t
Telescope's Field of View
Telescope's Field of View
B r i gh t n es s
B r i gh t n es s
C o n tr o l D i a l
C o n tr o l D i a l
R e d D o t
Re d D o t
A i min g
A i mi n g
N e e d l e
N e e d l e
Gu i d e li n e
G u i de l i n e
B ri g h tn e s s
Br i g h tn e s s
C o nt r o l D i a l
C on t ro l D i al

Advertisement

Table of Contents
loading

Related Products for Vixen X002518

This manual is also suitable for:

Porta ii

Table of Contents