Helios FDR Installation And Operating Instructions Manual

Differential humidity control
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Helios Ventilatoren
MONTAGE- UND BETRIEBSVORSCHRIFT
INSTALLATION AND OPERATING INSTRUCTIONS
NOTICE DE MONTAGE ET D´UTILISATION
Feuchtedifferenzregelung
Differential humidity control
Régulation de l'humidité différentielle
FDR
zur Steuerung von Lüftungsgeräten zur optimalen
Regulierung der Raumfeuchte
for controlling ventilation units for optimal room
humidity regulation
pour la commande des appareils de ventilation pour
une régulation optimale de l'humidité ambiante
DE
EN
FR

Advertisement

Table of Contents
loading

Summary of Contents for Helios FDR

  • Page 1 Helios Ventilatoren MONTAGE- UND BETRIEBSVORSCHRIFT INSTALLATION AND OPERATING INSTRUCTIONS NOTICE DE MONTAGE ET D´UTILISATION Feuchtedifferenzregelung Differential humidity control Régulation de l‘humidité différentielle zur Steuerung von Lüftungsgeräten zur optimalen Regulierung der Raumfeuchte for controlling ventilation units for optimal room humidity regulation pour la commande des appareils de ventilation pour une régulation optimale de l‘humidité...
  • Page 2: Table Of Contents

    Anschluss an Kleinraumventilator MiniVent ® M1/150 ............Seite 4 KAPITEL 4 INBETRIEBNAHME  SEITE 5 Betriebsarten ......................... Seite 5 LED-Statusanzeige ........................ Seite 5 App Helios FDR ........................Seite 5 4.3.1 Startbildschirm ........................Seite 5 4.3.2 Gerät hinzufügen ........................ Seite 6 4.3.3 Einstellungen ........................
  • Page 3: Wichtige Informationen

    Wenn die nachfolgenden Ausführungen nicht beachtet werden, entfällt unsere Gewährleistung. Gleiches gilt für Haftungsansprüche an den Hersteller. Der Gebrauch von Zubehörteilen, die nicht von Helios empfohlen oder angeboten werden, ist nicht statthaft. Even tuell auftretende Schäden unterliegen nicht der Gewährleistung.
  • Page 4: Einsatzbereich

    Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR 1.8 Einsatzbereich Die Feuchtedifferenzregelung FDR dient zur Steuerung von Lüftungsgeräten zur opti- malen Regulierung der Raumfeuchte (z.B. Kellerräume). Die Temperatur und die relative Feuchte der Raumluft werden bedarfsorientiert angepasst, um bspw. die Kondensation von Wasser an den Außenwänden zu verhindern.
  • Page 5: Montage

    Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR KAPITEL 3 3.1 Montage Bei der Auswahl des Montageorts sind folgende Installationshinweise zu beachten, da MONTAGE UND es sonst zu Beeinträchtigungen der Funktion von Regler und Sensoren kommen kann. INSTALLATION Installationshinweise Regler (Innenwand) – Regler nicht in der direkten Zuluft installieren.
  • Page 6 Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR 322 Anschluss an Kleinraumventilator MiniVent ® M1/100 Abb5 250 V AC, 6 A (2 A ind. Last) 12 V DC 50 mA 4 5 6 7 8 9 10 11 12 13 14 230 V...
  • Page 7: Betriebsarten

    LED leuchtet grün – Übertragung der Sensorwerte: LED blinkt grün – Fehlermeldung: LED leuchtet rot 4.3 App Helios FDR Die App „Helios FDR“ kann auf Google Play (Android) oder im im App Store (iOS) herunter- geladen werden. 4.3.1 Startbildschirm Startseite Impressum Sprache Gerät hinzufügen...
  • Page 8: Einstellungen

    Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR 432 Gerät hinzufügen ù ä Master PIN: 0000 ⓘ  Der PIN Code kann in den Einstel- lungen unter „Gerätestatus“ geändert werden. ò ë Gerätename beliebig wählbar. ü Aktuelle Werte ö Regler 4-stellige Gerätenummer beliebig wählbar.
  • Page 9 Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR 433 Einstellungen ⓘ  Das Gerät kann nur ausgewählt werden, wenn das Feld rot hinterlegt ist. Ist das Feld grau hinter- legt, ist das Gerät nicht in Reichweite. ò Schritt zurück ä Ausgewähltes Gerät â...
  • Page 10 Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR – AC: Schaltleistung: 0...+6 A (0,5 A-Schritte) Betriebsart: Dauer-, Automatik, Intervallbetrieb Werkseinstellung: Intervallbetrieb Nur bei Intervallbetrieb: Ventilator EIN: 1-120 Min. Werkseinstellung: 10 Min. Ventilator AUS: 1-120 Min. Werkseinstellung: 20 Min. ê Grundlüftung Werden die Bedingungen zur Entfeuchtung nicht erreicht, wird der Raum in bestimmten, einstellbaren Zeitintervallen mit frischer Luft durchspült.
  • Page 11 Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR – Schaltzeiten ändern/löschen â Schaltzeit ändern ù ä ê Schaltzeit löschen ò ù ⓘ  Die Änderungen der Schaltzeiten werden sofort an die Steuerung übertragen. á Tasterfunktion Festlegung der Nachlaufzeit nach Betätigung des externen Tasters.
  • Page 12: Gerät Entfernen

    Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR – Testfunktion: Der Regler wird deaktiviert, so dass manuelle Eingaben möglich sind – AC-Ventilator: EIN / AUS – Relais 2: EIN / AUS – EC-Ventilator: 0...+10 V – Offsetwerte: Möglichkeit, die Messwerte der Sensoren anzupassen, um einbauspezi- fische Abweichungen zu korrigieren.
  • Page 13 Montage- und Betriebsvorschrift Feuchtedifferenzregelung – FDR...
  • Page 14 ® M1/150 ............... Page 4 CHAPTER 4 COMMISSIONING  PAGE 5 Operating modes ........................Page 5 LED status display ......................... Page 5 Helios FDR App ........................Page 5 4.3.1 Home screen ........................Page 5 4.3.2 Add device ......................... Page 6 4.3.3...
  • Page 15: Chapter 1 Basic Information

    Our warranty shall not apply if the following instructions are not observed. The same applies for liability claims against the manufacturer. The use of accessories, which are not recommended or offered by Helios, is not permitted. Any damage that may occur is not liable for warranty.
  • Page 16: Function

    Installation and Operating Instructions Differential humidity control – FDR The differential humidity control is designed for use in the internal (control) or external area (external sensor). Do not expose the unit to direct sunlight. Any use other than the intended use is not permitted! 1.9 Function...
  • Page 17: Chapter 3 Assembly And Installation

    Installation and Operating Instructions Differential humidity control – FDR CHAPTER 3 3.1 Assembly ASSEMBLY AND When selecting the installation location, the following installation instructions should be observed, as otherwise functional impairments of the control and sensors may occur. INSTALLATION Installation instructions Control (internal wall) –...
  • Page 18 Installation and Operating Instructions Differential humidity control – FDR 322 Connection to small room fan MiniVent ® M1/100 Fig5 250 V AC, 6 A (2 A ind. load) 12 V DC 50 mA 4 5 6 7 8 9 10 11...
  • Page 19: Chapter 4 Commissioning

    – Transmission of sensor values: LED flashes green – Error report: LED lights up red 4.3 Helios FDR App The App Helios FDR is available to download from the App Store (iOS) or Google Play (Android). 4.3.1 Home screen Homepage...
  • Page 20: Settings

    Installation and Operating Instructions Differential humidity control – FDR 432 Add device ù ä Master PIN: 0000 ⓘ  The PIN Code can be changed in the settings under “Device status”. ò ë Device name is freely selectable. ü Current values ö...
  • Page 21 Installation and Operating Instructions Differential humidity control – FDR 433 Settings ⓘ  The device can only be selected if the box has a red background. If the box has a grey background, the device is not within range. ò Step back ä...
  • Page 22 Installation and Operating Instructions Differential humidity control – FDR – AC: Switching capacity: 0...+6 A (0,5 A steps) Operating mode: Continuous, auto., interval mode Factory setting: Interval operation Only for Interval operation: Fan ON: 1-120 min. Factory setting: 10 min.
  • Page 23 Installation and Operating Instructions Differential humidity control – FDR – Change/delete switching times â Change switching time Cancel ù ä ê Delete switching time ò ù ⓘ  The changes to switching times will be immediately transferred to the control. á...
  • Page 24: Remove Device

    Installation and Operating Instructions Differential humidity control – FDR – Test function: The control is deactivated so that manual entries are possible – AC fan: ON / OFF – Relay 2: ON / OFF – EC fan: 0...+10 V – Offset values: Option to adjust the sensor measurement values to correct installation- specific deviations.
  • Page 25 Installation and Operating Instructions Differential humidity control – FDR...
  • Page 26 M1/150 ............ Page 5 CHAPITRE 4 MISE EN SERVICE  PAGE 5 Modes de fonctionnement ..................... Page 5 Affichage de l‘état des LED ....................Page 5 Application Helios FDR ......................Page 5 4.3.1 Écran d‘accueil........................Page 6 4.3.2 Ajout d‘un appareil ......................Page 7 4.3.3...
  • Page 27: Informations Importantes

    Si toutes les consignes indiquées dans cette notice ne sont pas correctement respectées, la garantie s’annule. Idem pour les garanties constructeur Helios. L’utilisation d’acces- soires, non fournis, non conseillés ou non proposés par Helios, est interdite. Tous chan- gements ou transformations effectués sur l’appareil sont interdits, altèrent sa conformité...
  • Page 28: Fonctionnement

    Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR pour une régulation optimale de l‘humidité de la pièce (par exemple les pièces en sous- sol). La température et l‘humidité relative de l‘air ambiant sont ajustées en fonction des besoins, par exemple pour éviter la condensation sur les murs extérieurs. La régulation d‘humidité...
  • Page 29: Dimensions

    Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR 2.2 Dimensions Fig 2 Fig 3 Régulateur Capteur extérieur CHAPITRE 3 3.1 Montage Lors du choix de l‘emplacement de montage, les instructions d‘installation suivantes MONTAGE ET doivent être respectées, sinon le fonctionnement du régulateur et des capteurs peut être INSTALLATION altéré.
  • Page 30: Raccordement Sur Moteur Ec/Ac

    Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR 321 Raccordement sur moteur EC/AC Fig 4 Connexion moteur EC 230 V AC, 6 A (2 A charge ind.) 0-10 V Moteur 12 V DC 2 mA 50 mA 4 5 6 7...
  • Page 31: Modes De Fonctionnement

    La LED s‘allume en vert – Transmission des valeurs du capteur : La LED clignote en vert – Message d‘erreur : La LED s‘allume en rouge 4.3 Application Helios FDR L‘application Helios FDR peut être téléchargée depuis l‘App Store ou Google Play :...
  • Page 32: Écran D'accueil

    Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR 431 Écran d‘accueil Page de démarrage Mentions légales Langue Ajouter un appareil Retour à l‘écran d‘accueil...
  • Page 33: Paramètres

    Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR 432 Ajout d‘un appareil Code : 0000 ⓘ  Le code PIN peut être modifié dans les paramètres sous „État de l‘appa- reil“. Tout nom d‘appareil peut être sélectionné. Tout numéro d‘appareil à 4 chiffres peut être sélectionné.
  • Page 34 Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR 433 Paramètres ⓘ  L‘appareil ne peut être sélectionné que si le champ est surligné en rouge. Si le champ est surligné en gris, l‘appareil n‘est pas accessible (hors de portée).
  • Page 35 Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR max. : +2...+10 V Réglage usine 10 V – AC : Intensité max. du relais: 0...+6 A (0,5 A) Mode de fonct.: Fonctionnement continu, auto- matique, à intervalles Réglage usine : Fonctionnement à...
  • Page 36 Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR û Programme hebdomadaire Le programme hebdomadaire peut être actif ou inactif. Le programme hebdomadaire est utilisé pour désactiver la fonction de ventilation automatique pendant une période définie. Si le programme hebdomadaire est désactivé, le régulateur est actif en permanence.
  • Page 37: Retirer L'appareil

    Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR ó État de l‘appareil – Date/heure : – Date/heure : automatique (synchronisation avec la date/heure via un smart phone/tablette) – Heure d‘été : Sans / Europe – Fonction test : Le régulateur est désactivé...
  • Page 38: Démontage Et Recyclage

    Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR 435 Démontage et recyclage DANGER m DANGER Lors du démontage, les parties sous tension peuvent déclencher un choc électrique Avant le démontage, mettre le ventilateur hors tension et éviter tout redémarrage intempestif ! Les pièces, composants et matériel démonté...
  • Page 39 Notice de montage et d‘utilisation Régulation d‘humidité différentielle – FDR...
  • Page 40 HELIOS Ventilatoren GmbH + Co KG · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Le Carré des Aviateurs · 157 avenue Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstraße 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd.

Table of Contents