MODBUS Sensor Data Requests
Measurements all have a resolution of 0.1 but are reported as 10*.
8.2 m/s is returned as a value 82. The user must /10 in order to reinsert the
decimal precision.
Address
Register
200
201
201
202
202
203
203
204
204
205
205
206
206
207
207
208
208
209
210
211
211
212
212
213
213
214
† If not applicable to ULP-M, the register should report a value of zero (0).
* See Data Format section for numeric conversions.
ULP STD
User manual
Access
Response
Type
Range
Read
0 to 15†
Read
0 to 500*
Read
0 to 3599*
Read
0 to 500*
Read
0 to 3599*
Read
0 to 500*
Read
0 to 3599*
Read
0 to 500*
Read
0 to 3599*
Read
0 to 500*
Read
0 to 3599*
Read
0 to 500*
Read
0 to 3599*
Data
Description
Type
16-bit
System
Signed
Status†
Int
16-bit
Wind speed
Signed
(m/s) (3
Int
second
moving
average)
16-bit
Wind
Signed
direction (°)
Int
(3 second
moving
average)
16-bit
2 min avg
Signed
wind speed
Int
16-bit
2 min avg
Signed
wind
Int
direction
16-bit
10 min avg
Signed
wind speed
Int
16-bit
10 min avg
Signed
wind
Int
direction
16-bit
Wind gust
Signed
speed
Int
16-bit
Wind gust
Signed
direction
Int
16-bit
5 min avg
Signed
wind speed
Int
16-bit
5 min avg
Signed
wind
Int
direction
16-bit
5 min Wind
Signed
gust speed
Int
16-bit
5 min Wind
Signed
gust
Int
direction