Summary of Contents for Calypso ULP STD

  • Page 1 . c a l y p s o i n s t r u m e n t s . c o m CALYPSO INSTRUMENTS ULTRA-LOW-POWER ULTRASONIC STD (ULP STD) WIND METER User manual ULTRASONIC Portable User manual 0809 English version 3.0...
  • Page 2 If you want to know more about our new ULP STD wind meter, please keep reading or visit our website www.calypsoinstruments.com...
  • Page 3: Product Overview

    0. Index 1. Product overview 1. Product overview Thank you for choosing the ULP STD wind meter from Calypso Instruments. This is the 2. Package content first model or our generation II, representing an important technology breakthrough condensing 3. Technical specifications an extensive R+D investment: 3.1.Dimensions...
  • Page 4: Technical Specifications

    Sample rate: 0.1 Hz to 10 Hz · Height: 65 mm (2.56 in.) 3.2. Weight 210 grams (7.4 ounces) · 3.3-18 VDC 3.3 Power The ULP STD has to be connected as shown in this section. ULP STD User manual 04/14...
  • Page 5 3. Technical specifications A wide range of accessories can be used with the device. The ULP STD can be mounted on a flat service and screwed on to different sizes of poles. It can also be used with an adaptor for poles of 39 mm.
  • Page 6: Configuration Options

    5. Configuration Options The ULP STD can be set up by using a special configuration app made by Calypso Instru- ments. In order to use the app, you should download the configurator from our website at www.calypsoinstruments.com. To configure your device, connect the ULP via...
  • Page 7 6. Wait to complete configuration and when the system advises that it is finished, disconnect the USB and cables. 7. Your unit is now configured. 3º When the Device is Configurated NEW! ULP STD User manual 07/14...
  • Page 8: Communication Protocols

    DATA (A+) FIVE_WIND_GUST_DIR DIR_BASE_LA1 + 213 6.1.2 Modbus Configuration The ULP STD can be set up by using a special configuration app made by Calypso Instruments. In order to use the app, you should download the 6.2 RS485 Wiring, Configuration and Re- configurator from our website at www.calypsoinstruments.com.
  • Page 9 6.2.2 RS485 Configuration The connection is straightforward with no confi- guration required in RAW mode configuration. The ULP STD can be set up by using a special configuration app made by Calypso Instruments. MWV Wind Speed and Angle In order to use the app, you should download the...
  • Page 10 The ULP STD can be set up by using a special every time you ask for data: configuration app made by Calypso Instruments.
  • Page 11 I2C Address (1 Byte) + Register Address (1 Byte) Address -0x15 (21 decimal) Available Registers: Wind Raw Stat - 0x10 Wind 2 Min Stat - 0x12 Wind 5 Min Stat - 0x15 Wind 10 Min Stat - 0x1A Wind Full Stats - 0x1F ULP STD User manual 11/14...
  • Page 12: General Information

    In this configuration, speed the sensors within a 2 meter radius, for exam- reading (0-45m/s), scaled in a range of 4-20mA, ple, the mast head on a boat. is given through the channel we select. ULP STD User manual 12/14...
  • Page 13 Any wrongful use given by the user will not incur Other important aspects: in any responsibility on part of Calypso Instru- ments. Therefore, any harm caused to the ULP - Do not attempt to access the transducers area with your fingers;...
  • Page 14 Read 0 to 3599* 16-bit 5 min Wind Signed gust direction † If not applicable to ULP-M, the register should report a value of zero (0). * See Data Format section for numeric conversions. ULP STD User manual 14/14...
  • Page 15 Ultra-Low-Power Ultrasonic wind meter STD (ULP STD) User manual English version 3.0 30.05.23...