CO29A and CO29FF Ice Maker/Refrigerators 2 Inspect and Plan You have received a carton containing your CO29A or CO29FF Ice Maker/Refrigerator with a package inside containing a User Manual, a Product Registration Card and water connection parts. Complete and mail the Product Registration Card or register online at www.U-LineService.com.
CO29A and CO29FF Ice Maker/Refrigerators 3 Prepare Site Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for water and electrical connections in the rear.
Wall 1/4" Min. 21-7/16" 22-3/8" 90° Door Swing Right-Hand Hinge Wall or Wall or 1” Cabinet Cabinet Min. 145° Door Swing Left-Hand Hinge – Flush with Cabinet or Wall Adjacent to Cabinet or Wall Figure 3 02/2005 CO29A and CO29FF Ice Maker/Refrigerators Reversing the Door All units may be left- or right-hand opening.
CO29A and CO29FF Ice Maker/Refrigerators 5. Relocate plastic spacer/ bushing on bottom of door to opposite side, and place door on Bushing bottom hinge pin. See Figure 8. Clean out bushing hole in door bottom with a screwdriver if necessary. 6.
4 Prepare and Install Door Panel Units will accept a Custom 1/4" Thick Insert to harmonize with or accent the surrounding decor. If this treatment is not included in this installation, go on to 5 Adjust Door. Custom 1/4" Thick Door Panel Insert Door Panel Preparation A custom door panel can be inserted into the doorframe.
(see Figure 18). However, make certain that the tubing is not pinched or damaged during installation. • U-Line recommends the use of copper tubing for installation. To connect to water supply: 1. Install the 1/4 inch OD copper water line from the main water source.
Water Connection Figure 16 Figure 17 2. Locate the compression fitting and ferrule packed with the unit. Slide the compression fitting and ferrule over the 1/4-inch OD water supply line. Do not use thread sealing compound or tape. Using two wrenches, tighten the compression fitting on the supply line (see Figure 16).
CO29A and CO29FF Ice Maker/Refrigerators 8 Level the Unit Leveling Information IMPORTANT It is extremely important that the unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly. Use a level to check the levelness of the unit from front to back and from side...
Always throw away all ice cubes made during the first twenty-four (24) hours of operation. The ice bucket MUST be fully inserted to avoid freezing products in the refrigerator section. The ice bin door must be fully closed. Figure 24...
See the User Manual’s Troubleshooting Guide for more solutions. For more than four decades, U-Line has distinguished itself as the leader in built-in undercounter ice making, refrigeration and wine storage appliances. U-Line Corporation, located in Milwaukee, WI, is a family operated manufacturer of built-in undercounter icemakers, Combo refrigerators, refrigerated drawers and refrigerator/freezers.