United States Stove US2500E-P Owner’s Instruction And Operation Manual
United States Stove US2500E-P Owner’s Instruction And Operation Manual

United States Stove US2500E-P Owner’s Instruction And Operation Manual

Advertisement

Quick Links

Owner's Instruction and Operation Manual
Model Numbers:
US2500E-P • US2500E-BP
US2500E-L • US2500E-BL
Report Number: F19-487
Tested Per EPA Methods ALT-125, ASTM E2515,
ASTM E3053 and CSA B415
Certified to UL 1482-2022, CAN/ULC S627:2023
Mobile home/transportable building approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
© 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
Save These Instructions In A Safe Place For Future Reference.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
853578J-0606M
www.P65warnings.ca.gov
Ph. 800-750-2723

Advertisement

Table of Contents
loading

Summary of Contents for United States Stove US2500E-P

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 This app is available only Text to 423-301-5624 or; on the App Store for iPhone and iPad. Email us at: Search US Stove. Save your receipt with customerservice@usstove.com your records for any claims. © 2023 United States Stove Company...
  • Page 3: Installation Checklist

    Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: ______________________________________ Print Name: __________________________________Date: ______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2023 United States Stove Company...
  • Page 4: Tools And Materials

    Mount the flue collar to the top of the unit as shown using the (3) 5/16-18 x 1-1/2 bolts, (3) washers, and (3) weld tabs provided in the parts box. 5/6-8 x 1-1/2 BOLT WASHER GASKET HEATER TOP WELD TAB © 2023 United States Stove Company...
  • Page 5: Installation

    A wood stove IN A FACTORY-BUILT FIREPLACE must never be installed in a hallway or near a staircase, since it may block the way in case of fire or fail to respect required clearances. © 2023 United States Stove Company...
  • Page 6: Floor Protector

    • The chimney connector must not pass through an attic supplied with the air intake kit. Outside combustion air or roof space, closet or similar concealed space, a floor, may be required if: or a ceiling. © 2023 United States Stove Company...
  • Page 7 8 GA copper wire using a serrated or star • THE STOVE MUST BE ATTACHED TO THE washer to penetrate paint or protective coating to ensure STRUCTURE MOBILE HOME/ grounding. TRANSPORTABLE BUILDINGS. © 2023 United States Stove Company...
  • Page 8: Chimney Connector (Stove Pipe)

    Therefore the gas which circulates will cool and “plugging” of the chimney. An inadequate draft more slowly, thus reducing the build-up of creosote will cause the appliance to leak smoke into the room and the risk of chimney fires. © 2023 United States Stove Company...
  • Page 9: Factory Built Chimney

    Be sure to the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed. © 2023 United States Stove Company...
  • Page 10 • A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling. © 2023 United States Stove Company...
  • Page 11 The upper layer of wood should be Your heating appliance was designed to burn well protected from the element but not the sides. A good seasoned natural wood only; no other materials should © 2023 United States Stove Company...
  • Page 12: Testing Your Wood

    (see the wood heater in a manner inconsistent with operating “Fuel Recommendations” section of this manual). instructions in this manual. Burning unseasoned wet wood only hurts your stoves © 2023 United States Stove Company...
  • Page 13 Visible smoke consists of unburned fuel and moisture medium position (midway between the “Low” and “Hi” leaving your stove. Learn to adjust the air settings of your position). specific unit to produce the smallest amount of visible © 2023 United States Stove Company...
  • Page 14: Chimney Maintenance

    If creosote has accumulated (3 mm or more), it should be removed to reduce the risk of a chimney fire. © 2023 United States Stove Company...
  • Page 15: Glass Care

    It is recommended that you use both smoke and CO monitors in areas having the potential to generate CO. © 2023 United States Stove Company...
  • Page 16: How To Order Repair Parts

    DO NOT INSTALL IN AN ALCOVE non-combustible pad that will provide ember protection. DO NOT INSTALL IN ANY FIREPLACE The 450 mm (18 in) ember protection required on any © 2023 United States Stove Company...
  • Page 17: Repair Parts

    Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2023 United States Stove Company...
  • Page 18 Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2023 United States Stove Company...
  • Page 19: Service Record

    Engineer Name: ____________________________________ Engineer Name: ____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: __________________________________________ Company: __________________________________________ Telephone No.: _____________________________________ Telephone No.: _____________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: ____________________________________ Items Replaced: ____________________________________ © 2023 United States Stove Company...
  • Page 20 NOTES © 2023 United States Stove Company...

This manual is also suitable for:

Us2500e-bpUs2500e-lUs2500e-bl

Table of Contents