Prepare The New Overlay Panel - U-Line Echelon 2115WCOL Installation Instructions

Echelon series overlay door panel for wine captain models 2175wcol and 2115wcol
Hide thumbs Also See for Echelon 2115WCOL:

Advertisement

Overlay Panel Kit Parts Supplied
Item
Part
Number
1
12029-BLK
Top Pivot Plate - Black
2
12041
Insert 8mm Plug
3
20002
Screw #6 x 1.0 Pan HD
Mounting Instructions,
4
30138
21XX (not shown)
WC Overlay Prep Sheet,
5
30139
21XX (not shown)
6
31672
Door Closer - Male
7
31673
Door Closer - Female
Foam Tape .093 x .375 x
8
35003
8' (not shown)
Zipper Bag (holding
9
35003
closer ASM) (not shown)
10
42096
Pivot Post
11
42122
Screw #6 x .50 Lg Flat HD
Figure 1
www.U-LineService.com
Description
Quantity
1
2
10
1
1
1
1
1
1
2
2
ULIN_0412_A

Prepare the New Overlay Panel

Refer to the Overlay Panel Preparation instruction sheet,
part number 30139.
IMPORTANT
The overlay door panel must not weigh more than
20 lbs. The thickness of the door panel must be 3/4".
Remove Gasket from Door
1. Remove door from shipping box.
2. Turn door over so gasket is facing up. Pull door gasket
out of the groove completely. Start in the middle and
pull outward, moving toward the edge (Figure 2). This
may take some force, but be careful.
Figure 2
3. Place gasket on a flat, clean surface.
Checking Overlay Fit
If panel does not seat properly, determine the cause
of the problem by reviewing the Preparation
Instructions P/N 30139.
NOT FULLY SEATED
Figure 3
1. Lay overlay panel on front side of door. Make sure
panel is fully seated on all four sides.
2. Visually check for gap between panel and glass. If there
is an objectionable gap, continue to Applying Foam
Tape to Overlay.
3. If there is little or no gap between panel and glass,
continue to Attaching the Overlay Panel.
2
DOOR
GASKET
ULIN_0414_A
CAUTION
LITTLE OR NO GAP
OBJECTIONABLE GAP
ULIN_0415_A