Part
Assy Case Brake
Flow meter
Inlet
Outlet
Figure
Preparation:
• Make sure to disconnect the power, water supply,
• Remove the upper & lower baskets in the
• Pull out the dishwasher carefully.
1. Remove the two (2) screws of the frame left.
2. Remove the frame left.
3. . Remove cover brake by rotating.(counterclockwise)
4. Loosen the four (4) clamps and release the four (4)
Description
and drain hose connections.
dishwasher.
Caution
Make sure to wear gloves when removing it. Be
careful as the steel plate is sharp and may cut you.
Use a jig. If you do not have a jig, you can use a
needle nose pliers.(Be careful when removing the
cover as it is easily damaged.)
hoses from the Assy case brake.
Caution
Water remaining in the Assy case sensor and Assy
case break will come out. Lay a towel on the floor to
absorb any water that may come out.
Disassembly and Reassembly _ 23