Page 1
User Manual WISE-2460 Modbus Smart Vibration Sensor(10KHz@1-axis)
Page 2
No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. The information provided in this manual is intended to be accurate and reliable.
Page 3
This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This type of cable is available from Advantech. Please contact your local supplier for ordering information.
Build the Connection Between WISE-2460 and PC........6 WISE-2460 Device information ..............7 WISE-2460 Device System Configuration ..........8 WISE-2460 Sensor configuration and value output verification ....9 Table 2.1: Status ............... 10 WISE-2460 Sensor Calibration Mode ............. 12 Get time-domain raw data from WISE-2460 ........... 12 Figure 2.1 Get raw data - dashboard.........
WISE-2460 is a robust RS-485 smart vibration sensor integrated with an ARM Cor- tex-H7 processor, 10KHz@1-axis high detection range accelerometer and tempera- ture sensor. This powerful computing device balances the bandwidth between edge devices and the application service on the user side.
Go to WISE-2460 website, and download, install WISE Studio software on user’s PC Connect WISE-2460 to PC via a RS-485 to USB converter, and open WISE Stu- dio software. If user’s serial port on the left side is active, please click “Go to Configuration”...
User can click the “Device Info” on the top to check the Device Name, Firmware version, Boot loader Version and I/O Board firmware version. User can also goes to the information page and check more device information in detail, like serial number of this device, sensitivity setting of this WISE-2460, etc. WISE-2460 User Manual...
WISE-2460 Device System Configuration WISE-2460 has 4 sub-pages for device configuration setting, which are Time, Con- trol, RS-485 and Firmware. Time & Date: setting the RTC on WISE-2460 Control: can reset the WISE-2460 back to default or force reboot it.
WISE-2460 Sensor configuration and value output verification WISE-2460 has 2 sub-pages for sensor setting, which are Status and Configuration. Status: check the output value from WISE-2460. Detail values definition and default settings are below for reference. WISE-2460 User Manual...
Page 16
Band Temperature (⁰C) Internal system temperature value Configuration: WISE-2460 has 4 main settings for sensors, 3 for vibration sen- sor, 1 for temperature sensor. Range and feature enable settings for vibration data(Channel 0) WISE-2460 User Manual...
Page 17
WISE-2460. Vibration alarm setting: warning limit setting of Overall(Velocity RMS) value between 10~1,000Hz range. WISE-2460 will cross checking this value when the measurement interval arrives. Range, offset and alarm settings for temperature data (Channel 1).
User can also restore default sensitivity by click “Reset Sensitivity” button. Get time-domain raw data from WISE-2460 User can get the real time time-domain raw data from WISE-2460 directly. It will take around 40s for getting one raw data from WISE-2460. User can refer following pro- cess for getting the data on WISE Studio.
Page 19
Zoom in directly on the dashboard. Can reset the zoom level via zoom reset button. User can enable “Mark Chart Point” function. It’s more easier for reading the data on WISE Studio dashboard Figure 2.1 Get raw data - dashboard WISE-2460 User Manual...
Page 20
Figure 2.2 Get raw data - dashboard with mark WISE-2460 User Manual...
Advantech pairs WISE-2460 with WISE-4051 as a package for wireless applications. Once user finished the physical connection between WISE-2460 and WISE-4051. They can login WISE-4051 web and go to “Advantech Sensor” page for quick con- figuration setup. Please go to IO Status > COM1 > Modbus/RTU Configuration > Advantech Sensor.
WISE-4051 remotely. User can open WISE Studio and click “Query Raw Data” button on the top side to initial this function. The rest operation process are as same as WISE-2460. User can refer “Get time- domain raw data from WISE-2460” session for more detail.