Advantech WISE-2460 User Manual

Modbus smart vibration sensor

Advertisement

Quick Links

User Manual
WISE-2460
Modbus Smart Vibration
Sensor(10KHz@1-axis)

Advertisement

Table of Contents
loading

Summary of Contents for Advantech WISE-2460

  • Page 1 User Manual WISE-2460 Modbus Smart Vibration Sensor(10KHz@1-axis)
  • Page 2 No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. The information provided in this manual is intended to be accurate and reliable.
  • Page 3 This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This type of cable is available from Advantech. Please contact your local supplier for ordering information.
  • Page 4 WISE-2460 User Manual...
  • Page 5: Table Of Contents

    Build the Connection Between WISE-2460 and PC........6 WISE-2460 Device information ..............7 WISE-2460 Device System Configuration ..........8 WISE-2460 Sensor configuration and value output verification ....9 Table 2.1: Status ............... 10 WISE-2460 Sensor Calibration Mode ............. 12 Get time-domain raw data from WISE-2460 ........... 12 Figure 2.1 Get raw data - dashboard.........
  • Page 6 WISE-2460 User Manual...
  • Page 7: Chapter 1 Hardware Profile

    Chapter Hardware Profile...
  • Page 8: Common Specification

    WISE-2460 is a robust RS-485 smart vibration sensor integrated with an ARM Cor- tex-H7 processor, 10KHz@1-axis high detection range accelerometer and tempera- ture sensor. This powerful computing device balances the bandwidth between edge devices and the application service on the user side.
  • Page 9: Led Behavior

    Quick blink RED Initial fail Quick blink YELLOW Receive data Quick blink GREEN Send data Dimension 46.0 40.0 58.4 52.4 1/4-28 UNF M12 Connector Pin Define Table 1.2: M12 Connector Pin Define Pin Number Pin Name Data+ Data- WISE-2460 User Manual...
  • Page 10 WISE-2460 User Manual...
  • Page 11: Chapter 2 Software Settings

    Chapter Software Settings...
  • Page 12: Build The Connection Between Wise-2460 And Pc

    Go to WISE-2460 website, and download, install WISE Studio software on user’s PC Connect WISE-2460 to PC via a RS-485 to USB converter, and open WISE Stu- dio software. If user’s serial port on the left side is active, please click “Go to Configuration”...
  • Page 13: Wise-2460 Device Information

    User can click the “Device Info” on the top to check the Device Name, Firmware version, Boot loader Version and I/O Board firmware version. User can also goes to the information page and check more device information in detail, like serial number of this device, sensitivity setting of this WISE-2460, etc. WISE-2460 User Manual...
  • Page 14: Wise-2460 Device System Configuration

    WISE-2460 Device System Configuration WISE-2460 has 4 sub-pages for device configuration setting, which are Time, Con- trol, RS-485 and Firmware. Time & Date: setting the RTC on WISE-2460 Control: can reset the WISE-2460 back to default or force reboot it.
  • Page 15: Wise-2460 Sensor Configuration And Value Output Verification

    WISE-2460 Sensor configuration and value output verification WISE-2460 has 2 sub-pages for sensor setting, which are Status and Configuration. Status: check the output value from WISE-2460. Detail values definition and default settings are below for reference. WISE-2460 User Manual...
  • Page 16 Band Temperature (⁰C) Internal system temperature value Configuration: WISE-2460 has 4 main settings for sensors, 3 for vibration sen- sor, 1 for temperature sensor. Range and feature enable settings for vibration data(Channel 0) WISE-2460 User Manual...
  • Page 17 WISE-2460. Vibration alarm setting: warning limit setting of Overall(Velocity RMS) value between 10~1,000Hz range. WISE-2460 will cross checking this value when the measurement interval arrives. Range, offset and alarm settings for temperature data (Channel 1).
  • Page 18: Wise-2460 Sensor Calibration Mode

    User can also restore default sensitivity by click “Reset Sensitivity” button. Get time-domain raw data from WISE-2460 User can get the real time time-domain raw data from WISE-2460 directly. It will take around 40s for getting one raw data from WISE-2460. User can refer following pro- cess for getting the data on WISE Studio.
  • Page 19 Zoom in directly on the dashboard. Can reset the zoom level via zoom reset button. User can enable “Mark Chart Point” function. It’s more easier for reading the data on WISE Studio dashboard Figure 2.1 Get raw data - dashboard WISE-2460 User Manual...
  • Page 20 Figure 2.2 Get raw data - dashboard with mark WISE-2460 User Manual...
  • Page 21: Chapter 3 Modbus Table Of Wise-2460

    Chapter Modbus Table of WISE-2460...
  • Page 22 Acceleration RMS (0.001 g or 0.01 m/s2) 40073~40074 0 (Z) / Band 6 Read 40075~40076 0 (Z) / Band 7 Read 40077~40078 0 (Z) / Band 8 Read 40079~40080 0 (Z) / Band 9 Read 40081~40082 0 (Z) / Band 10 Read WISE-2460 User Manual...
  • Page 23 0 (Z) / Band 8 Read 40099~40100 0 (Z) / Band 9 Read 40101~40102 0 (Z) / Band 10 Read 40103~40104 Temperature (0.001⁰C) Read 40105~40106 0 (Z) Sensor status Read 40107~40108 Crest factor (0.001) Read 40109~40110 Measuring Timestamp Read WISE-2460 User Manual...
  • Page 24 Table 3.2: WISE-2460 Configuration settings Modbus address Address 4X Channel Description Attribute 40201 0 (Z) Range code 40202 40221 All channels Channel enable mask 46001 All bands Band enable mask 46002 0 (Z) Feature Enable Mask 46003 All channels Alarm enable mask...
  • Page 25: Wise-4051 & Wise-2460 Wireless Package Solution Settings

    Chapter WISE-4051 & WISE- 2460 Wireless Package Solution Settings...
  • Page 26: Basic Setting On Wise-4051

    Advantech pairs WISE-2460 with WISE-4051 as a package for wireless applications. Once user finished the physical connection between WISE-2460 and WISE-4051. They can login WISE-4051 web and go to “Advantech Sensor” page for quick con- figuration setup. Please go to IO Status > COM1 > Modbus/RTU Configuration > Advantech Sensor.
  • Page 27: Get Wise-2460 Time-Domain Raw Data From Wise-4051

    WISE-4051 remotely. User can open WISE Studio and click “Query Raw Data” button on the top side to initial this function. The rest operation process are as same as WISE-2460. User can refer “Get time- domain raw data from WISE-2460” session for more detail.
  • Page 28 No part of this publication may be reproduced in any form or by any means, such as electronically, by photocopying, recording, or otherwise, without prior written permission from the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. © Advantech Co., Ltd. 2023...

Table of Contents