Page 1
CO2 Sensor ® Featuring LoRaWAN LEO-S573-C2G0 / LEO-S573-C2C0 User Guide...
Page 2
In order to protect the security of the device, please change device password when first c onfiguration. The default password is 123456. ❖ The device is not intended to be used as a reference sensor, and Advantech will not should responsibility for any damage which may result from inaccurate readings. ❖...
Page 4
LoRaWAN enables encrypted radio transmissions over long distance while consuming very little power. The user can obtain sensor data and view the trend of data change through Advantech IoT Cloud or through the user's own Network Server. 1.2 Features ⚫...
Page 5
If any of the above items is missing or damaged, please contact your sales representative. 2.2 Hardware Overview LEO-S573-C2G0 sensors is made up of a LoRa transceiver and a sensor. Front View of LEO-S573-C2G0: ①LoRaWAN ® Antenna (Internal) ②NFC Area ③Vent Tube...
Page 6
Light Off: Device is off. 3. Operation Guide 3.1 Log in the ToolBox LEO-S573-C2G0 can be monitored and configured via ToolBox App or ToolBox software. Before configuration, ensure the insulating sheet inside the device has be pulled out and battery is not placed reversed.
Page 7
3.1.2 USB Configuration 1. Download ToolBox software from Advantech website. 2. Release the enclosure of the LEO-S573-C2G0 transceiver, then connect the device to a computer via Type-C port. 3. Open the ToolBox and select type as “General”, then click password to log in ToolBox.
Page 8
LoRaWAN settings is used for configuring the transmission parameters in LoRaWAN network. 3.2.1 Basic LoRaWAN Settings: Go to Device->Setting->LoRaWAN Settings of ToolBox App to configure join type, App EUI, App Key and other information. You can also keep all settings by default. www.advantech.com...
Page 9
30 mins; If no reply after specific Rejoin Mode packets, the device will re-join. Reporting interval > 30 mins: device will send specific mounts of LoRaMAC packets to check connection status every reporting interval; If no reply after www.advantech.com...
Page 10
Examples: 1, 40: Enabling Channel 1 and Channel 40 1-40: Enabling Channel 1 to Channel 40 1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60 All: Enabling all channels Null: Indicates that all channels are disabled www.advantech.com...
Page 11
Description Reporting interval of transmitting data to network server.Default: 10 mins, Reporting Interval Range: 1-1080 mins. For LEO-S573-C2G0 sensor, change the temperature unit displayed on the ToolBox. Temperature Unit Note: 1) The temperature unit in the reporting package is fixed as °C.
Page 12
Barometric Pressure Calibration: this only works when barometric sensor is enabled. Manual Calibration: Put the device in an open outdoor environment for more than 10 minutes and click this button to calibrate the CO2 value. Factory Calibration Restored: Clean the manual calibration and turn back to factory calibration www.advantech.com...
Page 13
LEO-S573-C2G0 will upload the current data instantly after the threshold is triggered. 3.4.4 Data Storage LEO-S573-C2G0 supports storing 1000 data records locally and exports data via ToolBox App or software. The device will record the data according to reporting interval even not joining network.
Page 14
4. Click Data Cleaning to clear all stored data inside the device if necessary. 3.4.5 Data Retransmission LEO-S573-C2G0 supports data retransmission to ensure network server can get all data even if network is down for some reasons. There are two ways to get the lost data: ⚫...
Page 15
3. After the network connected back, the device will send the lost data from the point in time when the data was lost according to the reporting interval. www.advantech.com...
Page 16
3.5.1 Upgrade ToolBox Software: 1. Download firmware from Advantech website to your PC. 2. Go to “Maintenance -> Upgrade” of ToolBox software, click “Browse” to import firmware and upgrade the device. You can also click “Up to Date” to search for the latest firmware of the device and upgrade.
Page 17
3.5.2 Backup LEO-S573-C2G0 support configuration backup for easy and quick device configuration in bulk. ® Backup is allowed only for devices with the same model and LoRaWAN frequency band. 1. Go to “Template” page on the App and save current settings as a template. You can also edit the template file.
Page 18
Go to “Device->Maintenance” to click “Reset”, then attach smart phone Via ToolBox App: with NFC area to device to complete reset. 4. Installation LEO-S573-C2G0 support wall, pole and DIN rail mounting. Before installation, ensure the mounting bracket has fixed to the device via screws. www.advantech.com...
Page 19
LEO-S573-C2G0 should be considered following notes to insure proper installation: ⚫ sensor should be mounted no higher than 12-18 inches above the floor since CO heavier than normal air and will flow down. ⚫ Installation should be considered the layout of a space. Enclosed spaces or varying spaces are recommended to install one more sensor.
Page 20
5. Device Payload 5.1 Uplink Payload 5.1.1 Device Information LEO-S573-C2G0 report basic information of device whenever joining the network. Channe Type Description 01(Protocol Version) 01=>V1 09 (Hardware Version) 01 40 => V1.4 0a (Software Version) 01 14 => V1.14 0b (Power On)
Page 21
68 27=>27 68=10088* (Barometric 0.1=1008. Pressure) 8 hPa 5.1.3 Temperature Mutation Threshold LEO-S573-C2G0 supports to report temperature mutation threshold alarm which has a different format with normal threshold alarm. Channel Type Description d7 (Mutation Temperature(2B) + Mutation Value(2B) + 02...
Page 23
Command format: Channel Type Description 6b (Enquire data in time point) 4 Bytes, unix timestamp Start time (4 bytes) + End time (4 bytes), 6c (Enquire data in time range) Unix timestamp www.advantech.com...
Page 24
Data format: Sensor Description (2B) + Pressure (2B) + Temperature (2B) + LEO-S573-C2G0 Humidity (1B) Note: 1. The device only uploads no more than 300 data records per range enquiry. 2. When enquiring the data in time point, it will upload the data which is closest to the search point within the reporting interval range.
Page 25
20ce b1c36164 c9036427010175 Channel Type Time Stamp Value CO2: c9 03 => 03 c9 = 969ppm b1c36164 => ce (Historical Temperature: 6461c3b1=2023/0 Data) 0101=>101=257*0.1=25.7°C 5/15 13:31:00 Humidity: 75=>117*0.5=58.5% -END- www.advantech.com...