Yamaha F25 Service Manual page 26

Hide thumbs Also See for F25:
Table of Contents

Advertisement

Item
Neutral switch
Input voltage (*1)
Thermo sensor
Resistance (*1)
at 75 °C (167 °F)
Charge coil
Resistance (*1)
at 20 °C (68 °F)
Output peak voltage
at cranking (unloaded)
at cranking (loaded)
at 1500 r/min (loaded)
at 3500 r/min (loaded)
CDI unit
Output peak voltage
at cranking (loaded)
at 1500 r/min (loaded)
at 3500 r/min (loaded)
Item
Spark plug
Gap
Cap resistance (*1)
Ignition coil
Primary coil resistance (*1)
at 20 °C (68 °F)
Secondary coil resistance
(*1)
(spark plug wire – spark plug
wire)
at 20 °C (68 °F)
Pulser coil
Air gap
Resistance (*1)
at 20 °C (68 °F)
Output peak voltage
at cranking (unloaded)
at cranking (loaded)
at 1500 r/min (loaded)
at 3500 r/min (loaded)
Neutral switch
Input voltage (*1)
Thermo sensor
Resistance (*1)
at 75 °C (167 °F)
Model data / Electrical technical data
Unit
F25MHA
V
kΩ
V
V
V
V
V
V
V
Unit
F25EA
mm (in)
kΩ
kΩ
mm (in)
V
V
V
V
V
kΩ
Model
F25EHA
12.0
0.372
28.9–39.1
70.0
110.0
190.0
190.0
210.0
180.0
180.0
Model
F25A
0.8–0.9 (0.031–0.035)
5.0
0.26–0.35
6.8–10.2
0.8 (0.031)
152.0–228.0
4.5
2.7
4.1
6.5
12.0
0.372
1
T25A
1-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T25F25mhaF25ehaF25eaF25aT25a

Table of Contents