Pfaff 260 Service Manual page 89

Hide thumbs Also See for 260:
Table of Contents

Advertisement

2. Turn stitch width
dial
A
to
"4".
3.
Turn eccentric stud A in
the
needle
bar
frame pitman (Fig.
107) so
that its
lobe
is
at the top.
4.
Turn eccentric
.
s tud
B (Fig. 106)
to
set the needle bar as for to
the
right
(toward the
balance
wheel) as possible.
5.
Loosen
zigzag
regulator crank on zigzag regulator stud b (Fig.
1 04)
just
sufficiently
to
permit the Iotter to be
adjusted
from above with the aid of o
slender screwdriver.
6. Push zigzag finger-tip
control
F up as far as it will go and,
7. while the machine is running, adjust zigzag regulator stud b
so that
the
needle bar makes
no vibrating
motion.
8.
Release
zigzag finger-tip
control
F and
tighten the set
screw on the zigzag
regulator crank. Again push up zigzag finger-tip control
F
and
check
to
see
that the
needle bar does not swing
sideways.
9. Set
stitch
width
dial
A on "0", run the machine and turn regulating
screw
e
(Fig.
104)
to
the right or left, as appropriate, until the needle bar
ceases to
swing sideways.
10.
Turn
stitch
width dial A to
"4"
and set needle position
lever
Bat
its central
position. Turn eccentric stud A
(Fig.
107) to center
the
needl·e in
the
needle
plate slot.
11. Rotate
the
bevel gear on the arm shaft until the needle, as it descends on
the
right and left of its throw, ceases vibrating when its point has reached o
position about
5
/32N
to
1
/•N, or 4 to 6 mm, above the
needle
plate.
(See
also
the second paragraph on page 48).
12.
Turn stitch width dial A to
"0",
and set needle position lever B at
its
left
position.
13.
Depress zigzag finger-tip
control
F repeatedly
to check
whether the needle
does not
vibrate.
If adjustment
is
required,
loosen
hexagon screw
c
on the
needle position com finger (Fig. 104) and
the
lock nut on regulating screw d,
and
turn
this screw in or out while operating zigzag finger-tip control F,
until any needlle vibration has been eliminated. This will normally be the
case
when the clearance at f (Fig.
104)
is
5 /32",
or 4
mm.
14. Put needle position
lever
B
in
the central notch.
15. Adjust the needle throw in relation to the center line
in
the needle plate
slot by means of eccentric stud B
(Fig. 106).
To make this adjustment, turn
stitch
width dial A to
"4",
then to
"0".
16. Set stitch width dial A on "0" and put needle position
lever
B in the
central
notch.
Turn
eccentric stud A (Fig. 107), as
may
be appropriate to center the
needle
in
the needle
plate
slot.
17. Double-check the position of
the
needle and of the needle throw
in
relation
to the needle plate slot and, if necessary, repeat the adjustments discussed
in
paragraphs 15 and 16 above. To check the correct setting, place a piece
of cardboard under the needle.
Important
Having made this adjustment conscientiously,
tighten
all
set screws
securely.
88

Advertisement

Table of Contents
loading

This manual is also suitable for:

360