HPE 606A Operating And Servicing Manual page 4

High frequency signal generator
Table of Contents

Advertisement

Model 606A
SPECIFICATIONS
FREQUENCY RANGE:
50 ke to 65 mc in 6 bands.
50 -
170 kc
1.7
165 -
560kc
5.8
- 19.2 mc
530 - 1800 kc
9.0
FREQUENCY
ACCURACY:
Within +1%.
FREQUENCY CALIBRATOR:
Crystal oscillator provides check points at 100 kc (useful
to 6 mc) and 1 mc
intervals, accurate
within 0.01% from
0°to 50°C,
RF OUTPUT
LEVEL:
Continuously adjustable from 0.1 pv to 3 volts into a 50 ohm
resistive load.
Calibration is in volts and dbm (0 dbm is
1 milliwatt).
OUTPUT
ACCURACY:
Within +1 db into 50 ohm resistive load.
FREQUENCY RESPONSE:
Within
+1 db into 50 ohm resistive load over entire fre-
quency range at any output level setting.
OUTPUT IMPEDANCE:
50 ohms,
swr
less
than 1.1 on 0.3 volt range;
on 1 volt
and 3 volt
ranges,
less
than
1.1 to 20 mc and less than
1.2 to 65 mc.
BNC
output connector mates with UG-88A/
B/C/D.
SPURIOUS
HARMONIC OUTPUT:
Less than 3%.
LEAKAGE:
Negligible;
permits
receiver
sensitivity
measurements
down to at least 0.1 microvolt.
AMPLITUDE MODULATION:
Continuously
adjustable
from
0 to 100%.
Indicated
bya
panel meter.
Modulation
level is constant within +1/2 db
regardless of carrier frequency and output level changes.
INTERNAL MODULATION:
0 to
100%
sinusoidal
modulation
at
400
cps
45% or
1000 cps +5%.