3 Port valve control set
= EARTH
= LIVE
= NEUTRAL
T
2
C
1
V
Fig. 63
Greenstar Danesmoor Kitchen
ErP+
and Kitchen System
Grey
Orange
White
Blue
Yellow/Green
N1 1 2 3 4 5 6 6a
ErP+ -
6 720 821 686 (2018/04)
Terminal connector block (G):
R
> Remove link 1 to 3.
> Remove link 2 to 4.
> Make link 3 to 5.
Optional 230V Worcester
programmer (P):
Blue
> Set the pin on the rear of the
programmer to 'pumped'.
S
> Remove the link plug (H).
> Connect the plug from
programmer (P) into connector (F).
> Move the orange wire from
terminal 9 to terminal 6.
Brown
Key to components:
[R]
Room thermostat
[S]
Circulating pump
[F]
Internal programmer connector
[G]
Terminal block connector
[H]
Link connector
[T]
Hot water cylinder thermostat
[V]
Mid position valve
[P]
Optional 230V Worcester programmer
(fitted in the fascia panel)
G
7 8 9 10
F
H
Orange
P
6720808218-51.1Wo