Connecting the Device to the Electricity Supply

The device must be connected to a properly earthed socket in line with
Ÿ
the relevant valid country regulations.
4.7.1
Plug connection (for United Kingdom only)
If a 3-pin plug is used, it should be fitted with a 3 amp fuse,
with other plug types, the circuit should contain a 5 amp fuse.
Warning - This appliance must be earthed.
IMPORTANT
The wires in the mains lead of this appliance
are coloured in accordance with the following
code:
GREEN and YELLOW
BLUE
BROWN
As the colours of the wires in the mains lead
may not correspond with the coloured markings
identifying the terminals in your plug, proceed as
follows.
1. Connect the GREEN and YELLOW coloured wire to the plug terminal
marked letter E or earth symbol or coloured green or green and yellow.
2. Connect the BROWN coloured wire to the plug terminal marked letter L
or coloured red.
3. Connect the BLUE coloured wire to the plug terminal marked letter N or
coloured black.
Moulded-On Plug Version
The mains lead is fitted with a non-rewirable moulded-on plug con-
taining a 3 amp fuse. If the fuse requires replacing at any time, the fuse
cover/carrier should be removed using a small screwdriver to level out. The
old fuse should be replaced by a 3 amp ASTA approved BS1362 fuse and
the fuse cover/carrier must be refitted before the plug is used again.
If the fuse cover-carrier is lost, a replaceement can be obtained from the
Dometic service Shops.
The fuse cover/carrier must be of the same colour as that of the coloured
insert in the base of the plug. In no circumstances must the plug be used
without a correct fuse cover/carrier fitted. ......
If the connection cable is damaged it must be replaced by the
Customer Service at Dometic, or by respectively qualified personnel,
in order to prevent any hazards.
Attention: For GB Only !
Check prior to initial operation that the voltage
Ÿ
noted on the model label corresponds to the
mains voltage.
If this is not the case, do not connect the
device and contact your dealer!
: EARTH
: NEUTRAL
: LIVE
7