Locating; Leveling Cabinet - True TCGDZ-50 Installation Manual

Tcgdz display cases (dual zone)
Hide thumbs Also See for TCGDZ-50:
Table of Contents

Advertisement

True Food Service Equipment, Inc.

LOCATING

Warning
For proper performance of refrigerated cabinet an
ambient temperature no greater than 75°F (24°C)
with a relative humidity of 55% is required.
TOOLS REQUIRED:
• Phillips screw driver
3
/
" (9.5 mm) socket or
8
Step 2
A. Use a Phillips screw diver and remove four
screws from the L-bracket connected the unit to
the wood skid (image 1). Then use a 3/8" (9.5
mm) socket or wrench and remove the L-brack-
et from the unit (image 2).
To avoid damage to glass DO NOT lay cabinet on its
side or back when removing skid, installing leg
levelers, cleaning, etc.
B. Lift up from the base and walk unit off the skid
and set in final location.
C. Unblock doors, (free plastic wedges, blue foam
LEVELING
Step 3
A. Set unit in its final location. Be sure there is
adequate ventilation in your room. Under extreme
heat conditions, (100˚F +, 38˚C+), you may want to
install an exhaust fan.
Warning
Warranty is void if ventilation is insufficient.
A. Proper leveling of your True unit is critical to
operating success (for non-mobile models).
Effective condensate removal and door operation
will be effected by leveling.
Warning
Display case must be leveled accurately to ensure
front glass door seals properly.
B. The unit should be leveled front to back and
side to side with a level. Place the level in the
interior floor of the unit and check all four sides.
5
INSTALLATION / OPERATION INSTRUCTIONS
3
/
" (9.5 mm) wrench
8
............ www.truemfg.com ............
and tape. Remove fiberglass tape securing glass.
Remove components: (shelves, brackets, etc.)
from inside cabinet.
1
Removing bracket
from skid.
C. If the cabinet is not level adjust leg levelers by
first relieving weight to leveler and adjusting by
either hand or wrench. Repeat with all leg level-
ers until cabinet is level in all directions.
D. Ensure that the drain hose or hoses are posi-
tioned in the pan.
E. Models with power cord: Free plug and cord
from inside the lower rear of the cooler (do not
plug in).
F. Models with power cord: The unit should be
placed close enough to the electrical supply so
that extension cords are never used.
Warning
Compressor warranties are void if the unit is more
than 9 ft. (3 m) from plug-in connection or an exten-
sion cord is used to connect unit to a power supply.
2
Removing bracket from cabinet.
5

Advertisement

Table of Contents
loading

Table of Contents