3 Transport
3
Transport
All of the products offered by Schmid AG energy solutions are transported by our own
specialists and delivered to the correct location. The components of the system are
protected against corrosion for transport and storage.
The components of the combustion system are delivered separately as follows:
•
Combustion grate incl. insulation
•
Hot water boiler with a built-in boiler door and multi-cyclone separator
•
Cladding plates, insulation mats for the combustion grate on pallets
•
Add-on components, flue-gas and supply air fans, damper actuators, various small
parts, on pallets
•
Control cabinet on pallets
If system components are temporarily stored, they should be covered to protect against
dirt and moisture.
The unprotected storage of electrical components as control cabinets, motors, etc. is
prohibited.
The following regulations must be complied with if the components are collected and
temporarily stored by our partners or customers:
•
Prevention of exposure to water
•
When transporting systems or system components are transported on open vehi-
cles, suitable packaging is necessary for protection against the effects of the weather
and soiling.
•
Prevention of vibrations as far as possible
•
Never expose systems and system components to temperatures of below -20°C (risk
of brittling breakage)
•
Suitable packaging must be used for sea transport (preferably overseas shipping
container), wooden crates should never be loaded on deck for shipping
•
Corrosion protection is necessary for all modes of transport
•
Transport vehicles must be equipped with pneumatic or hydraulic suspension to pre-
vent vibration breakage.
Danger from falling loads!
Falling loads can cause serious injury.
System components may only be lifted by the lifting brackets designed for that purpose
and only in the presence of our specialists.
Use only suitable, tested, and approved lifting equipment.
Never stand or work under suspended loads.
Underfeed grate UTSK
1.10 en
i
WARNING!
D-37