SIGMATEK SE 051 Instruction Manual

S-dias splitter ethernet

Advertisement

Quick Links

SE 051
S-DIAS Splitter Ethernet
Instruction Manual
Date of creation: 03.12.2014
Version date: 26.07.2023
Article number: 20-023-051-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE 051 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIGMATEK SE 051

  • Page 1 SE 051 S-DIAS Splitter Ethernet Instruction Manual Date of creation: 03.12.2014 Version date: 26.07.2023 Article number: 20-023-051-E...
  • Page 2 (print, photocopy, microfilm or in any other process) without the express permission. We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in the handbook and assumes no responsibility for damages that occur...
  • Page 3 S-DIAS Splitter Ethernet SE 051 with 5 Ethernet interfaces The S-DIAS SE 051 Ethernet splitter connects several network segments via 5 ports. Incoming data packets at one Ethernet port are distributed over the other ports. The splitter module is located in a double-wide S-DIAS housing.
  • Page 4: Table Of Contents

    SE 051 S-DIAS SPLITTER ETHERNET Contents Introduction ................4 Target Group/Purpose of this Operating Manual ...... 4 Important Reference Documentation ......... 4 Contents of Delivery ..............4 Basic Safety Directives ............5 Symbols Used ................5 Disclaimer ..................7 General Safety Directives ............8 Software/Training .................
  • Page 5 S-DIAS SPLITTER ETHERNET SE 051 Connector Layout ..............17 Front View ..................17 7.1.1 Status LEDs ..................17 7.1.2 Connectors..................18 Module View from Top..............18 Applicable Connectors ............... 19 Label Field ................... 20 Assembly/Installation ............21 Check Contents of Delivery ............21 Mounting ..................
  • Page 6: Introduction

    General knowledge of automation technology is required. Further help and training information, as well as the appropriate accessories can be found on our website www.sigmatek-automation.com. Our support team is happily available to answer your questions. Please see our website for our hotline number and business hours.
  • Page 7: Basic Safety Directives

    S-DIAS SPLITTER ETHERNET SE 051 Basic Safety Directives Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes: DANGER Danger indicates that death or serious injury will occur, if the specified measures are not taken.
  • Page 8 SE 051 S-DIAS SPLITTER ETHERNET INFORMATION Information  Provides important information on the product, handling or relevant sections of the documentation, which require attention. Page 6 26.07.2023...
  • Page 9: Disclaimer

    It does not guarantee properties under the warranty. Please thoroughly read the corresponding documents and this operating manual before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through, non-compliance with these instructions or applicable regulations.
  • Page 10: General Safety Directives

    SE 051 S-DIAS SPLITTER ETHERNET General Safety Directives The Safety Directives in the other sections of this operating manual must be observed. These instructions are visually emphasized by symbols. INFORMATION According to EU Directives, the operating manual is a component of a product.
  • Page 11: Software/Training

    S-DIAS SPLITTER ETHERNET SE 051 CAUTION Handle the device with care and do not drop or let fall. Prevent foreign bodies and fluids from entering the device. The device must not be opened! Manipulez l’appareil avec précaution et ne le laissez pas tomber.
  • Page 12: Standards And Directives

    The product was constructed in compliance with the following European Union directives and tested for conformity. 3.1.1 EU Conformity Declaration EU Declaration of Conformity The product SE 051 conforms to the following European directives: • 2014/35/EU Low-voltage Directive • 2014/30/EU Electromagnetic Compatibility (EMC Directive) •...
  • Page 13: Type Plate

    S-DIAS SPLITTER ETHERNET SE 051 Type Plate HW: Hardware version SW: Software version 26.07.2023 Page 11...
  • Page 14: Technical Data

    INFORMATION Problems can arise if a control is connected to an IP network, which contains modules that do not run on a SIGMATEK operating system. With such devices, Ethernet packets could be sent to the control with such a high frequency (i.e. broadcasts), that the high interrupt load could cause a real-time runtime error or runtime error.
  • Page 15: Electrical Requirements

    S-DIAS SPLITTER ETHERNET SE 051 Electrical Requirements 18-30 V DC Supply voltage UL: Class 2 or LVLC typically: 45 mA at 18 V maximum: 50 mA at 18 V typically: 35 mA at 24 V maximum: 40 mA at 24 V...
  • Page 16 SE 051 S-DIAS SPLITTER ETHERNET Page 14 26.07.2023...
  • Page 17: Miscellaneous

    S-DIAS SPLITTER ETHERNET SE 051 Miscellaneous Article number 20-023-051 Standard UL 508 (E247993) Approbations UL, cUL, CE, UKCA Environmental Conditions Storage temperature -20 ... +85 °C Environmental temperature 0 ... +55 °C Humidity 0-95 %, non-condensing Installation altitude above sea...
  • Page 18: Mechanical Dimensions

    SE 051 S-DIAS SPLITTER ETHERNET Mechanical Dimensions Page 16 26.07.2023...
  • Page 19: Connector Layout

    S-DIAS SPLITTER ETHERNET SE 051 Connector Layout Front View 7.1.1 Status LEDs yellow LIGHTS switch IC running DC OK green LIGHTS module is supplied with a voltage > 18 V LIGHTS connection between the two PHYs made Ethernet Link/Active green...
  • Page 20: Connectors

    SE 051 S-DIAS SPLITTER ETHERNET 7.1.2 Connectors X1-X5: Ethernet 8-pin RJ45 Function Tx+/Rx+ Tx-/Rx- Rx+/Tx+ n.c. n.c. Rx-/Tx- n.c. n.c. n.c. = do not use Module View from Top Page 18 26.07.2023...
  • Page 21: Applicable Connectors

    S-DIAS SPLITTER ETHERNET SE 051 INFORMATION The connections of the +24 V supply (X6: Pin 1 and Pin 2) or the GND supply (X6: Pin 3 and Pin 4) are internally bridged. To supply the module, only one +24 V pin (pin 1 or pin 2) and one GND pin (pin 3 or pin 4) must be connected.
  • Page 22: Label Field

    SE 051 S-DIAS SPLITTER ETHERNET Label Field Manufacturer Weidmüller Type MF 10/5 CABUR MC NE WS Weidmüller article number 1854510000 Compatible printer Weidmüller Type Printjet Advanced 230V Weidmüller article number 1324380000 Page 20 26.07.2023...
  • Page 23: Assembly/Installation

    S-DIAS SPLITTER ETHERNET SE 051 Assembly/Installation Check Contents of Delivery Ensure that the contents of the delivery are complete and intact. See chapter 1.3 Contents of Delivery. INFORMATION On receipt and before initial use, check the device for damage. If the device is damaged, contact our customer service and do not install the device in your system.
  • Page 24: Mounting

    SE 051 S-DIAS SPLITTER ETHERNET Mounting The S-DIAS modules are designed for installation into the control cabinet. To mount the modules a DIN-rail is required. The DIN rail must establish a conductive connection with the back wall of the control cabinet. The individual S-DIAS modules are mounted on the DIN rail as a block and secured with latches.
  • Page 25 S-DIAS SPLITTER ETHERNET SE 051 Recommended minimum distances of the S-DIAS modules to the surrounding components or control cabinet wall: a, b, c … distances in mm (inches) 26.07.2023 Page 23...
  • Page 26: Transport/Storage

    SE 051 S-DIAS SPLITTER ETHERNET Transport/Storage INFORMATION This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! Temperature and humidity fluctuations may occur during transport.
  • Page 27: Maintenance

    S-DIAS SPLITTER ETHERNET SE 051 11 Maintenance INFORMATION During maintenance as well as servicing, observe the safety instructions from chapter 2 Basic Safety Directives. 11.1 Service This product was constructed for low-maintenance operation. 11.2 Repair INFORMATION In the event of a defect/repair, send the device with a detailed error description to the address listed at the beginning of this document.
  • Page 28 SE 051 S-DIAS SPLITTER ETHERNET Documentation Changes Change date Affected Chapter Note page(s) 26.03.2015 3.3 Applicable Connectors Added connections 21.01.2016 1.3 Electrical Requirements Standard changed 1.4 Miscellaneous 26.01.2016 1.3 Electrical Requirements Graphics added 28.04.2016 4 Mounting Graphics distances 17.08.2017 1.5 Environmental Conditions Added operating conditions 3.3 Applicable Connectors...

Table of Contents