SIGMATEK SE 052 Operating Manual

S-dias splitter ethernet
Hide thumbs Also See for SE 052:

Advertisement

Quick Links

SE 052
S-DIAS Splitter Ethernet
Operating Manual
Date of creation: 02.08.2019
Version date: 26.07.2023
Article number: 20-023-052-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE 052 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIGMATEK SE 052

  • Page 1 SE 052 S-DIAS Splitter Ethernet Operating Manual Date of creation: 02.08.2019 Version date: 26.07.2023 Article number: 20-023-052-E...
  • Page 2 (print, photocopy, microfilm or in any other process) without express permission. We reserve the right to make changes in the content without notice. SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in this handbook and assumes no responsibility for damages that occur through its...
  • Page 3 SE 052 with 5 Ethernet interfaces (Tyco Mini I/O) The S-DIAS SE 052 Ethernet splitter connects multiple network segments via 5 ports. Incoming data packets to an Ethernet port are distributed to the other ports. The splitter module is installed in a double-wide S-DIAS housing.
  • Page 4: Table Of Contents

    SE 052 S-DIAS SPLITTER ETHERNET Contents Introduction ................4 Target Group/Purpose of this Manual ........4 Contents of Delivery ..............4 Basic Safety Guidelines ............5 Symbols Used ................5 Disclaimer ..................7 General Safety Guidelines ............8 Residual Risks ...............10 Guidelines..................
  • Page 5 S-DIAS SPLITTER ETHERNET SE 052 Connector Layout ..............17 Front View ..................17 8.1.1 Status LEDs ..................17 8.1.2 Connectors..................18 Top View ..................18 Applicable Connectors ............... 19 Applicable Connector Cables ............ 20 Label Field ................... 21 Shielding ................22 10 Strain Relief ................
  • Page 6: Introduction

    SE 052 S-DIAS SPLITTER ETHERNET Introduction Target Group/Purpose of this Manual This manual contains all information required for operating the SE 052. This manual is intended for: • Project planners • Technicians • Commissioning engineers • Machine operators • Maintenance/test technicians General knowledge of automation technology is required.
  • Page 7: Basic Safety Guidelines

    S-DIAS SPLITTER ETHERNET SE 052 Basic Safety Guidelines Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes: DANGER Danger indicates that death or serious injury will occur, if the specified measures are not taken.
  • Page 8 SE 052 S-DIAS SPLITTER ETHERNET INFORMATION Information  Provides important information on the product, handling or relevant sections of the documentation, which require attention. CAUTION Danger for ESD-sensitive components. Les signes de danger pour les composants sensibles aux décharges électrostatiques.
  • Page 9: Disclaimer

    It does not guarantee properties under the warranty. Please thoroughly read the corresponding data sheets, operating instructions and this system handbook before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through non-compliance with these instructions or applicable regulations.
  • Page 10: General Safety Guidelines

    SE 052 S-DIAS SPLITTER ETHERNET General Safety Guidelines The Safety Directives in the other sections of this operating manual must be observed. These instructions are visually emphasized by symbols. INFORMATION According to EU Guidelines, the operating instructions are a component of a product.
  • Page 11 S-DIAS SPLITTER ETHERNET SE 052 CAUTION Handle the device with care and do not drop or let fall. Prevent foreign bodies and fluids from entering the device. The device must not be opened! Manipulez l’appareil avec précaution et ne le laissez pas tomber.
  • Page 12: Residual Risks

    Guidelines The panel was constructed in compliance with European Union guidelines. 3.1.1 EU Declaration of Conformity EU Declaration of Conformity The SE 052 conforms to the following European guidelines: • 2014/35/EU Low-voltage guideline • 2014/30/EU “Electromagnetic Compatibility” (EMC guideline) •...
  • Page 13: Type Plate

    S-DIAS SPLITTER ETHERNET SE 052 Type Plate HW: Hardware version SW: Software version 26.07.2023 Page 11...
  • Page 14: Technical Data

    INFORMATION Problems can arise if a control is connected to an IP network, which contains modules that do not contain a SIGMATEK operating system. With such devices, Ethernet packets could be sent to the control with such a high frequency (i.e. broadcasts), that the high interrupt load could cause a real-time runtime error or runtime error.
  • Page 15: Electrical Requirements

    S-DIAS SPLITTER ETHERNET SE 052 Electrical Requirements Supply voltage 18-30 V DC UL: Class 2 or LVLC typically: 45 mA at 18 V maximum: 50 mA at 18 V typically: 35 mA at 24 V maximum: 40 mA at 24 V...
  • Page 16: Environmental Conditions

    SE 052 S-DIAS SPLITTER ETHERNET Environmental Conditions Storage temperature -20 ... +85 °C Ambient temperature 0 ... +55 °C Humidity 0-95 %, non-condensing Installation altitude above sea 0-2000 m without derating level > 2000 m with derating of the maximum environment temperature by 0.5 °C...
  • Page 17: Mechanical Dimensions

    S-DIAS SPLITTER ETHERNET SE 052 Mechanical Dimensions 26.07.2023 Page 15...
  • Page 18: Esd Protection

    S-DIAS SPLITTER ETHERNET ESD Protection CAUTION Before any device is connected to or disconnected from the SE 052, the potential with ground should be equalized (by touching the control cabinet or ground terminal). Electrostatic loads (through clothing and shoes) can thereby be dissipated.
  • Page 19: Connector Layout

    S-DIAS SPLITTER ETHERNET SE 052 Connector Layout Front View 8.1.1 Status LEDs yellow LIGHTS switch-IC running DC OK green LIGHTS module is supplied with a voltage > 18 V LIGHTS connection between the two PHYs made Ethernet Link/Active green BLINKS data is exchanged over the Ethernet bus full duplex mode (LED does not light –...
  • Page 20: Connectors

    SE 052 S-DIAS SPLITTER ETHERNET 8.1.2 Connectors 1.1.1.1 X1-X5: Ethernet (Industrial Mini I/O) Function Tx+/Rx+ Tx-/Rx- Rx+/Tx+ n.c. Rx-/Tx- n.c. Top View Page 18 26.07.2023...
  • Page 21: Applicable Connectors

    S-DIAS SPLITTER ETHERNET SE 052 INFORMATION The connections of the +24 V supply (X6: Pin 1 and Pin 2) or the GND supply (X6: Pin 3 and Pin 4) are internally bridged. To supply the module, only one +24 V pin (pin 1 or pin 2) and one GND pin (pin 3 or pin 4) must be connected.
  • Page 22: Applicable Connector Cables

    SE 052 S-DIAS SPLITTER ETHERNET Applicable Connector Cables Ethernet: Cable type Length Article number RJ45 on industrial Mini I/O Type 1, drag chain capable 0.5 m 16-911-005 16-911-010 1.5 m 16-911-015 16-911-020 16-911-030 16-911-050 10 m 16-911-100 20 m 16-911-200...
  • Page 23: Label Field

    S-DIAS SPLITTER ETHERNET SE 052 Label Field Manufacturer Weidmüller Type MF 10/5 CABUR MC NE WS Article number Weidmüller 1854510000 Compatible printer Weidmüller Type Printjet Advanced 230V Article number Weidmüller 1324380000 26.07.2023 Page 21...
  • Page 24: Shielding

    The low-ohm shielding is either connected at the entry to the control cabinet or directly before the SE 052 over a large surface (cable grommets, grounding clamps)! Noise signals can therefore be prohibited from reaching the electronics and affecting the function.
  • Page 25: Strain Relief

    S-DIAS SPLITTER ETHERNET SE 052 10 Strain Relief INFORMATION The cable must be mounted close to the module (e.g. using a clamp)! No mechanical stress can be applied to the connection! 26.07.2023 Page 23...
  • Page 26: Assembly/Installation

    SE 052 S-DIAS SPLITTER ETHERNET 11 Assembly/Installation 11.1 Check Contents of Delivery Ensure that the contents of the delivery are complete and intact. See chapter 1.2 Contents of Delivery. INFORMATION On receipt and before initial use, check the device for damage. If the device is damaged, contact our customer service and do not install the device in your system.
  • Page 27: Mounting

    S-DIAS SPLITTER ETHERNET SE 052 11.2 Mounting The S-DIAS modules are designed for installation into the control cabinet. To mount the modules, a DIN-rail is required. The DIN rail must establish a conductive connection with the back wall of the control cabinet. The individual S-DIAS modules are mounted on the DIN rail as a block and secured with latches.
  • Page 28 SE 052 S-DIAS SPLITTER ETHERNET Recommended minimum distances of the S-DIAS modules to the surrounding components or control cabinet wall: a, b, c … distances in mm (inches) Page 26 26.07.2023...
  • Page 29: Transport/Storage

    S-DIAS SPLITTER ETHERNET SE 052 12 Transport/Storage INFORMATION This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! Temperature and humidity fluctuations may occur during transport.
  • Page 30: Maintenance

    SE 052 S-DIAS SPLITTER ETHERNET 14 Maintenance INFORMATION During maintenance as well as servicing, observe the safety instructions from chapter 2 Basic Safety Directives. 14.1 Service This product was constructed for low-maintenance operation. 14.2 Repair INFORMATION When sent for repair, the panel should be transported in the original packaging if possible.
  • Page 31 S-DIAS SPLITTER ETHERNET SE 052 Documentation Changes Change date Affected page(s) Chapter Note 04.06.2020 4.3 Electrical Table changed for Supply current over X6 Requirements 02.07.2020 4.4 Miscellaneous UL in preparation changed to UL 508 (E247993) 01.09.2020 7.2 Top View Text block inserted on top 04.11.2020...

Table of Contents