SIGMATEK SE 052 Technical Manual

S-dias splitter ethernet
Hide thumbs Also See for SE 052:

Advertisement

Quick Links

SE 052
S-DIAS Splitter Ethernet
Technical Manual
Date of creation: 02.08.2019
Version date: 02.08.2019
Article number: 20-023-052-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE 052 and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGMATEK SE 052

  • Page 1 SE 052 S-DIAS Splitter Ethernet Technical Manual Date of creation: 02.08.2019 Version date: 02.08.2019 Article number: 20-023-052-E...
  • Page 2 (print, photocopy, microfilm or in any other process) without express permission. We reserve the right to make changes in the content without notice. SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in this handbook and assumes no responsibility for damages that occur through its...
  • Page 3 SE 052 with 5 Ethernet interfaces (Tyco Mini I/O) The S-DIAS SE 052 Ethernet splitter connects multiple network segments via 5 ports. Incoming data packets to an Ethernet port are distributed to the other ports. The splitter module is installed in a double-wide S-DIAS housing.
  • Page 4: Table Of Contents

    SE 052 S-DIAS SPLITTER ETHERNET Contents Introduction ................4 Target Group/Purpose of this Manual ........4 Contents of Delivery ..............4 Basic Safety Guidelines ............5 Symbols Used ................5 Disclaimer ..................6 General Safety Guidelines ............7 Residual Risks ................ 8 Guidelines..................
  • Page 5 S-DIAS SPLITTER ETHERNET SE 052 7.1.1 Status LEDs ..................13 7.1.2 Connectors..................14 Top View ..................14 Applicable Connectors ............... 15 Applicable Connector Cables ............ 16 Label Field ................... 17 Shielding ................18 Strain Relief ................19 10 Transport/Storage ..............20 11 Mounting ................
  • Page 6: Introduction

    SE 052 S-DIAS SPLITTER ETHERNET Introduction Target Group/Purpose of this Manual This manual contains all information required for operating the SE 052. This manual is intended for: • Project planners • Technicians • Commissioning engineers • Machine operators • Maintenance/test technicians General knowledge of automation technology is required.
  • Page 7: Basic Safety Guidelines

    S-DIAS SPLITTER ETHERNET SE 052 Basic Safety Guidelines Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes: DANGER Identifies an immediate danger with high risk, which will lead to immediate death or serious injury if not avoided.
  • Page 8: Disclaimer

    Please thoroughly read the corresponding data sheets, operating instructions and this system handbook before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through non-compliance with these instructions or applicable regulations. The general and special safety instructions described in the following sections, as well as technical regulations, must therefore be observed.
  • Page 9: General Safety Guidelines

    Maintain this manual in readable condition and keep it accessible for reference. Operate the unit with devices and accessories approved by SIGMATEK only. CAUTION Handle the device with care and do not drop or let fall.
  • Page 10: Residual Risks

    Guidelines The panel was constructed in compliance with European Union guidelines. 3.1.1 EU Declaration of Conformity CE Declaration of Conformity The SE 052 conforms to the following European guidelines: • 2014/35/EU Low-voltage guideline • 2014/30/EU “Electromagnetic Compatibility” (EMC guideline) •...
  • Page 11: Technical Data

    Ethernet 5 Problems can arise if a control is connected to an IP network, which contains modules that do not contain a SIGMATEK operating system. With such devices, Ethernet packets could be sent to the control with such a high frequency (i.e. broadcasts), that the high interrupt load could cause a real-time runtime error or runtime error.
  • Page 12: Miscellaneous

    SE 052 S-DIAS SPLITTER ETHERNET Miscellaneous Article number 20-023-052 Hardware version Standard UL in preparation Approvals Environmental Conditions Storage temperature -20 ... +85 °C Ambient temperature 0 ... +55 °C Humidity 0-95 %, non-condensing Installation altitude above sea 0-2000 m without derating level >...
  • Page 13: Mechanical Dimensions

    S-DIAS SPLITTER ETHERNET SE 052 Mechanical Dimensions 02.08.2019 Page 11...
  • Page 14: Esd Protection

    SE 052 S-DIAS SPLITTER ETHERNET ESD Protection Before any device is connected to or disconnected from the SE 052, the potential with ground should be equalized (by touching the control cabinet or ground terminal). Electrostatic loads (through clothing and shoes) can thereby be dissipated.
  • Page 15: Connector Layout

    S-DIAS SPLITTER ETHERNET SE 052 Connector Layout Front View 7.1.1 Status LEDs green LIGHTS switch-IC running DC OK yellow LIGHTS module is supplied with a voltage > 18 V LIGHTS connection between the two PHYs made Ethernet Link/Active green BLINKS data is exchanged over the Ethernet bus full duplex mode (LED does not light –...
  • Page 16: Connectors

    SE 052 S-DIAS SPLITTER ETHERNET 7.1.2 Connectors 7.1.2.1 X1-X5: Ethernet (Industrial Mini I/O) Function Tx+/Rx+ Tx-/Rx- Rx+/Tx+ n.c. Rx-/Tx- n.c. Top View Page 14 02.08.2019...
  • Page 17: Applicable Connectors

    S-DIAS SPLITTER ETHERNET SE 052 Applicable Connectors Connectors: X1-X5: Industrial Mini I/O Plug Type 1 Lock Extend Version (not included in delivery) X6: Connectors with spring terminals (included in delivery) The spring terminals are suitable for the connection of ultrasonically compressed (ultrasonically welded) strands.
  • Page 18: Applicable Connector Cables

    SE 052 S-DIAS SPLITTER ETHERNET Applicable Connector Cables Ethernet: Cable type Length Article number RJ45 on industrial Mini I/O Type 1, drag chain capable 0.5 m 16-911-005 16-911-010 1.5 m 16-911-015 16-911-020 16-911-030 16-911-050 10 m 16-911-100 20 m 16-911-200...
  • Page 19: Label Field

    S-DIAS SPLITTER ETHERNET SE 052 Label Field Manufacturer Weidmüller Type MF 10/5 CABUR MC NE WS Article number Weidmüller 1854510000 Compatible printer Weidmüller Type Printjet Advanced 230V Article number Weidmüller 1324380000 02.08.2019 Page 17...
  • Page 20: Shielding

    The low-ohm shielding is either connected at the entry to the control cabinet or directly before the SE 052 over a large surface (cable grommets, grounding clamps)! Noise signals can therefore be prohibited from reaching the electronics and affecting the function.
  • Page 21: Strain Relief

    S-DIAS SPLITTER ETHERNET SE 052 Strain Relief The cable must be mounted close to the module (e.g. using a clamp)! No mechanical stress can be applied to the connection! 02.08.2019 Page 19...
  • Page 22: Transport/Storage

    SE 052 S-DIAS SPLITTER ETHERNET 10 Transport/Storage This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! CAUTION During transport, temperature and humidity fluctuations may occur.
  • Page 23: Mounting

    S-DIAS SPLITTER ETHERNET SE 052 11 Mounting The S-DIAS modules are designed for installation into the control cabinet. To mount the modules, a DIN-rail is required. The DIN rail must establish a conductive connection with the back wall of the control cabinet. The individual S-DIAS modules are mounted on the DIN rail as a block and secured with latches.
  • Page 24 SE 052 S-DIAS SPLITTER ETHERNET Recommended minimum distances of the S-DIAS modules to the surrounding components or control cabinet wall: a, b, c … distances in mm (inches) Page 22 02.08.2019...
  • Page 25: Maintenance

    S-DIAS SPLITTER ETHERNET SE 052 12 Maintenance WARNING During maintenance as well as servicing, observe the safety instructions from chapter 2. Lors de l'entretien et de la maintenance, respectez les consignes de sécurité du chapitre 2. 12.1 Service This product was constructed for low-maintenance operation.
  • Page 26: Disposal

    SE 052 S-DIAS SPLITTER ETHERNET 13 Disposal When disposing of the panel, the national electronic scrap regulation must be observed. The panel cannot be discarded with domestic waste. Page 24 02.08.2019...
  • Page 27 S-DIAS SPLITTER ETHERNET SE 052 Documentation Changes Change date Affected page(s) Chapter Note 02.08.2019 Page 25...
  • Page 28 SE 052 S-DIAS SPLITTER ETHERNET Page 26 02.08.2019...

Table of Contents