Trouble Shooting - FSP Technology EnerX 3000 User Manual

Portable energy storage system
Table of Contents

Advertisement

TROUBLE SHOOTING

Warning and Fault List
Code Type
Code #
Fault
F01
Fault
F02
Fault
F03
Fault
F04
Fault
F05
Fault
F06
Fault
F07
Fault
F08
Fault
F09
Fault
F10
Fault
F11
Fault
F12
Fault
F13
Fault
F14
Warning
W01
Warning
W02
Warning
W03
Warning
W04
Warning
W05
Warning
W06
Phenomenon and/or Possible cause
No response while press the main switch.
No Utility power and PV is applied.
No response while pressing the main switch.
Utility power or PV power exists.
Output turned off, Buzzer beeps continuously, RED LED solid on
F01 shows. Fans abnormal stopped during startup
sequence
F02 shows.
F03 shows.
F04 shows. Battery voltage dropped to an extremely
low level
Event
Code Type
Fan fault
Fault
High PV-volt
Fault
High bat-volt
Fault
Low bat-volt
Fault
Output S.C.
Fault
High op-volt
Fault
Low op-volt
Fault
High bus-volt
Fault
Low bus-volt
Fault
High PV-amp
Fault
High inv-amp
Fault
High bus-amp
Fault
High disc-amp
Fault
Over temp.
Fault
Grid not exist
Warning
PV not exist
Warning
Pack not exist
Warning
Weak SoC
Warning
Weak PV-volt
Warning
Power de-rate
Warning
What to do
Check whether the DC breaker tripped or has not yet
turned on?
If problem exist still, please contact the service center
to repair it.
Check whether the AC breaker tripped? Or PV voltage
reaches to the operation level?
If problem exist still, please contact the service center
to repair it.
Please contact service center to replace them.
Configure the PV panels lower than 450V.
Disconnect the Utility and PV power. Then, re-apply
again. If over-voltage alarm still, suppose the internal
charger with some problem, please contact with
service center to repair it.
Please contact the service center to check if battery
still in warranty period.
24
Code #
Event
F15
Bus start fault
F16
Inv start fault
F17
High dc offset
F18
Over-load
F19
Amp sense fault
F20
Backfeed fault
F21
Firmware fault
F22
Par-CAN fault
F23
Par-host fault
F24
Par-sync fault
F25
Par-bat fault
F26
Par-grid fault
F27
Par-opa fault
F28
Par-set fault
W07
Heavy load
W08
Temp issue
W09
Fan issue
W10
BMS lost
W11
Comm. Lost
W12
Par limited

Advertisement