Carrier 38BYC Installation And Start-Up Instructions Manual page 6

12 seer split system heat pump

Advertisement

4, Set room
them_ostat
to desired
temperature,
Be sure set point
is below
indoor=ambient
temperature
5, Set room them_ostat
to HEAT or COOL and fire control to ON
o1" A'LTO
mode,
as desired.
Operate
unit
fbr
15 minutes
Check
system=refi'igerant
charge.
SEQUEN(E
OF OPERATION
NOTE:
Defi'ost=control
board
may
be equipped
with
5-minute
lockout
timer that may be initiated
upon any interruption
of power.
With
power
supplied
to indoor
and outdoor
units,
trans*brmer
is
energized.
( OOLING
On a call _br cooling,
them_ostat
makes
circuits
R=O, R=¥, and
R-G. Circuit R=O energizes
reversing
valve, switching
it to cooling
position.
Circuit
R=Y energizes
contactor,
starting
outdoor=_im
motor
and compressor
circuit.
R-G energizes
indoor
unit=blower
relay,
starting
indoor=blower
motor
on high
speed.
When
thermostat
is satisfied,
its contacts
open,
de=energizing
the
contactor
and blower
relay. Compressor
and motors
should
stop.
NOTE:
If indoor
unit is equipped
with a time=delay
relay circuit,
the blower
runs an additional
90 sec to increase
system
efficiency.
HP THERMOSTAT
m
24 VAC
HOT
F_
24 VAC
COM
HEAT
STAGE
E_
COOL/HEAT
STAGE 1
INDOOR FAN
RVS COOLINC E_
EMERGENCY
HEAT
outdoor
temperature
fi_lls below
setting
of outdoor
thermostat
(field=installed
option),
contacts
close to complete
circuit and bring
on second
bank
of supplemental
electric
heat.
When
thermostat
is satisfied,
its contacts
open,
de-energizing
contactor
and relay.
All heaters
and motors
should
stop.
DEFROST
The defi'ost contlol
is a time/temperature
control
which includes
a
field=selectable
(quick=connects
located
at board edge)
time period
between
deflost
cycles
(30, 60, or 90 minutes),
factoQ
set at 90
minutes.
The electronic
timer and defrost
cycle start only when contactor
is
energized
and defi'ost
flaermostat
is closed.
Defi'ost mode
is identical
to cooling
mode except
that outdoor=fan
motor
stops
and
second-stage
heat
is turned
on to
continue
wamaing
conditioned
space.
To initiate
defi'ost, the defiost
thermostat
must be closed.
This can
be accomplished
as %llows:
1. Turn off power
to outdoor
unit.
2. Disconnect
outdoor=Jim
motor
lead
[i'om
OF2
on control
board.
(See Fig. 10.) Tape lead to prevent
grounding.
TYPICAL
HEAT
FAN COIL
PUMP
,a--D ---q4S
* IF AVAILABLE
Fig. g--Generic
Wiring
Diagram
(See Thermostat
Insta{iation
Instructions
for wiring
specific
unit combinations.)
LEGEND
24-V
FACTORY
WIRING
24-V FIELDWIRING
FIELDSPLICECONNECTION
ODT
OUTDOOR
THERMOSTAT
EMERGENCY
HEAT
RELAY
SUPPLEMENTAL
HEAT
RELAY
A02325
A97413
HEATING
On a call for heating,
thermostat
makes
circuits
R=¥
and R-G
(ircuit
R=¥
energizes
contactor,
starting
outdoor=_im
motor
and
compressor.
Circuit
R-G energizes
indoor-blower
relay,
starting
blower
motor
on high speed.
Should
temperature
continue
to
£fll,
R=W2
is made
through
second-stage
room=them_ostat
bulb,
Circuit
R-W2
energizes
a
relay,
bringing
on first bank
of supplemental
electric
heat and
providing
electrical
potential
to second
heater
relay
(if used)
If
3, Restart unit in heating mode, allowing[i'ost
to accumulate on
outdoor coil.
4. After a few minutes
in heating
mode,
liquid-line
temperature
should
drop below
closing
point
of defiost
thermostat
(ap=
proximately
30°F).
5. Short
between
speed=up
terminals
with
a flat=blade
screw-
&iver.
(See
Fig.
10)
This
reduces
the
timing
sequence
to
1/256th
of original
time. (See Table 3.)

Advertisement

loading

This manual is also suitable for:

38byg