8-4. Details of function

¢ Control input function
 When function setting is "Operation/Stop" mode 1
• In the case of "Edge" input
Mode
Function setting
0
46-00
 When function setting is "Forced stop" mode
• In the case of "Edge" input
Mode
Function setting
0
46-02
8-4. Details of function
60-00
On
CN15
Off
Operation
Indoor unit
Stop
Remote controller
60-00
On
CN15
Off
Forced stop
Normal
Operation
Indoor unit
Stop
Remote controller
External input
CN14
Input of indoor unit
CN15
On
External input
CN14
Input of indoor unit
CN15
On
- 19 -
Input signal
Command
Off → On
Operation
On → Off
Stop
Off → On
Operation
On → Off
Stop
Input signal
Command
Off → On
Forced stop
On → Off
Normal
Off → On
Forced stop
On → Off
Normal
On
On
8. External input and output