6-1 High Voltage Transformer; Magnetron; High Voltage Capacitor - Samsung 80089 Service Manual

Table of Contents

Advertisement

PRECAUTION
1.
High voltage is present at the high voltage terminals during any cook cycle.
2.
It is neither necessary nor advisable to attempt measurement of the high voltage.
3.
Before touching any oven components or wiring, always unplug the oven from its power source and
discharge the high voltage capacitor.
J
6-1 High Voltage Transformer
0_eQ_0e_0@Q0_Q0_eQ_0e_0OQ0_eQ0_eQ_0e_0OQ0_eQ00e_0_Q__@_0ee_Q__0@Q_
1.
Remove connectors from the transformer terminals and
Secondary
Filament
Primary
check continuity.
2.
Normal resistance readings are as follows:
SHV-U1870C
Approx. 129.5 D + 2%
Shows Continuity
Approx. 0.410 D + 2%
Approx. 0.475 D + 2%
Room temperature = 20°C)
Secondary
Filament
Terminal
Terminals
Primary
Terminal
6-2 IViagnetron
1.
Continuity checks can indicate only an open filament or
a shorted magnetron. To diagnose an open filament or
MagnetronAntenna
shorted magnetron.
Gasket Plate
2.
Isolate the magnetron from the circuit by disconnecting its
leads.
3.
A continuity check across the magnetron filament terminals
should indicate one ohm or less.
4.
A continuity check between each filament terminal and
magnetron case should read open.
Cooling
Fi
1.
Check continuity of the capacitor with the meter set at the highest resistance scale.
2.
Once the capacitor is charged, a normal capacitor shows continuity for a short time, and then indicates 9MQ.
3.
A shorted capacitor will show continuous continuity.
4.
An open capacitor will show constant 9MD.
5.
Resistance between each terminal and chassis should read infinite.
6-3 Nigh Voltage
Capacitor

Advertisement

Table of Contents
loading

This manual is also suitable for:

80082800848008680083

Table of Contents