6o14 Sensor
@@0@0@0@@@@@@000@000@O@@00@@@0O@0@0@0@@@0@@@0@@0@0@0@@@0@@@@O@@@@@@@@@@@@@@@@@@@@@@@
The Sensor Cooking Function uses a special gas sensor which detects
both humidity(steam) and hydrocarbons(food
odors) during the cooking
process. Before conducting either of the sensor tests below, ensure the
unit is plugged into a will outlet for at least 5 minutes, tf already plugged
in, proceed. The sensor is a plug-in device located in the vent area at
the top left hand corner of the cavity behind the grille.
To Service :
1.
Disconnect power and remove grille.
2.
Separate retainer from receptacle and unplug sensor.
SENSOR TEST (QUICK TEST)
1.
With 2 fingers touch and hold the following pads at the same time :
and
2.
Observe diagnostic number in display (Numbers approximate).
• 15-185 (Normal-verify with "detection test")
• 213 or Higher (Sensor failed to open, sensor unplugged, wiring or smart board.)
• Less then 6 (shorted sensor, or smart board).
NOTE : Only heater terminals ( H Black and Red leads) can be checked with ohmmeter(30Q).
CAUTION : DO NOTATTEMPT TO CHECK SENSOR TERMINALS (White and Orange leads).