EN
8.3 The appliance emits excessive noise.
Possible cause
Dust bag is full/ filters are dirty.
Motor may have degraded.
Carbon brush is worn out.
8.4 There is a burning smell from the appliance.
Possible cause
Carbon brush is worn out.
Windings exceed allowed operation
temperature.
8.5 The cord winder does not rewind the supply cord into the storage compartment while pressing the cable winder button.
Possible cause
Cord winder assembly is defective.
Solution
Refer to the User Manual to empty the dust bag, and clean or replace the filters.
Visually inspect the motor for signs of burnt winding. If the motor does not show defects in
appearance, quick check of measuring degradation of the resistance at the motor terminals using
ohmmeter.
Refer to chapter 9.3 to check and replace the motor.
Refer to chapter 9.3 to check and replace the motor.
Solution
Refer to chapter 9.3 to check and replace the motor.
Refer to chapter 9.3 to check and replace the motor.
Solution
Refer to chapter 9.4 to check and install the existing supply cord into a new cord winder assembly.
10