Download Print this page

Whirlpool AKR 315/IX/01 Instructions page 4

Built-in gas hob

Advertisement

PRODUCT DESCRIPTION
1. Removable panstand grids
2. Semi-rapid burner
3. Semi-rapid burner
4. Rapid burner
5. Auxiliary burner
6. Rapid burner
7. Control knobs
The symbols
are indicating which cooking field this knob activates.
Note: your hob aesthetics can be slightly different from the drawing. Burner placement and control symbols can vary.
PRATICAL ADVICE FOR USING THE BURNERS
This hob has burners of different diameters. For better burner performance,
please stick to the following rules:
-
Use pots and pans with bottoms the same width as that of the burners or
slightly larger (see table on the right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and keep the pot
covered.
-
Make sure pots on the grates do not protrude beyond the edge of the hob.
IMPORTANT: improper use of the grids can result in damage to the hob: do
not position the grids upside down or slide them across the hob.
Do not use:
-
Cast iron griddles, ollar stones, terracotta pots and pans.
-
Heat diffusers such as metal mesh, or any other types.
-
Two burners simultaneously for one receptacle (e.g. fish kettle).
HOW TO USE THE HOB
Do not let the burner flame extend beyond the edge of the pan.
WARNING
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
Symbols
Shaded circle
Tap closed
Large flame
Maximum opening/delivery
Small flame
Minimum opening or reduced delivery
Burner
Rapid
Semi-rapid
Auxiliary
The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit,
wait at least one minute before trying to light it again.
In the event of the burners flames being accidentally extinguished, turn off the burner control and do not attempt to
reignite it for at least one minute.
NOTE: should particular local conditions of the delivered gas make the ignition of burner difficult, it is advisable to repeat
the operation with the knob turned to small flame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this
case, repeat the operations described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: if the distance "A" between the wall cabinets is
between 600 mm and 730 mm, the height "B" must be a
minimum of 530 mm.
if the distance "A" between the wall cabinets is greater
than the width of the hob, the height "B" must be a
minimum of 400 mm.
In case of installation of a hood above the hob, please refer
to the hood instructions fot the correct distance.
INJECTORS TABLE
Pot Ø
Type of gas
Type of burner
From 24 to 26 cm
used
From 16 to 24 cm
From 8 to 14 cm
Rapid
NATURAL GAS
Semi-rapid
(Methane) G20
Auxiliary
Rapid
LIQUEFIED
PETROLEUM GAS
Semi-rapid
(Butane)
G30
Auxiliary
Rapid
LIQUEFIED
PETROLEUM GAS
Semi-rapid
(Propane)
G31
Auxiliary
Type of gas used
Model configuration
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 230 V ~ 50 Hz 0,6W
Injector
Rated thermal
Rated
marking
flow rate
consumption
kW
115 Y
3.00
286 l/h
95 Z
1.75
167 l/h
72 X
1.00
95 l/h
85
3.00
218 g/h
63
1.75
127 g/h
50
1.00
73 g/h
85
3.00
214 g/h
63
1.75
125 g/h
50
1.00
71 g/h
Rated thermal
4 BURNERS
flow rate (kW)
consumption
2 R - 2 SR - 1 AUX
10.50
2 R - 2 SR - 1 AUX
10.50
2 R - 2 SR - 1 AUX
10.50
CATEGORY II2H3+
Reduced heat
Gas pressure
capacity
mbar
kW
min.
rat.
max.
0.60
0.35
17
20
25
0.30
0.60
0.35
20
28-30
35
0.30
0.60
0.35
25
37
45
0.30
3
Total rated
Air required (m
) for
3
burning 1 m
of gas
1001 l/h
9.52
763 g/h
30.94
749 g/h
23.80

Advertisement

loading

This manual is also suitable for: