Display
The indicator lamp of
the Καθαρισμός
κάδου (Drum
Clean) programme
flashes
Other displays

Faults and what to do about them

Faults
Water is leaking from the
appliance.
The appliance is not filling
with water.
Detergent is not being dis-
pensed.
The wrong detergent/fab-
ric softener has been
poured into the dis-
penser(s).
Detergent/fabric softener
has congealed in the dis-
pensers.
The door cannot be
opened.
Cause/Remedy
Run the Καθαρισμός κάδου (Drum Clean) 90°C programme to clean and care
for the drum and the outer tub.
Notes
Run the programme without laundry.
Use washing powder or a detergent containing bleach. To prevent foaming,
only use half the amount of detergent recommended by the detergent manu-
facturer. Do not use detergent designed for woollens or delicates.
Switching the Καθαρισμός κάδου (Drum Clean) information signal on/off.
~ "Switching the drum-care information signal on/off" on page 40
Switch off the appliance, wait for five seconds and then switch it on again. If the dis-
play appears again, call customer service.
Cause/Remedy
Attach the drain hose correctly or replace it.
Tighten the screw fitting on the supply hose.
Programme does not start?
Is the water tap turned on?
Could the filter in the water supply be blocked?
~ "Filter in the water supply is blocked" on page 44
Is the supply hose kinked or trapped?
Dispenser(s):
Empty and clean.
1.
2.
Refill.
Clean and refill the dispensers.
Childproof lock activated? Deactivate childproof lock.
The temperature in drum is too high to open the door.
The safety function is activated. Stop the programme?
The water level in drum is too high.
Can the door only be opened by the emergency release?
~ "Emergency release" on page 45
Faults and what to do about them
en
47